Review
The ACiQ 2.5 ton split system represents the practical middle ground in residential HVAC equipment. It combines an upflow furnace capable of 60,000 BTU heating with an air conditioning condenser rated at 30,000 BTU cooling capacity. Built on Goodman's proven platform and configured with modern R454B refrigerant, this system appeals to contractors and homeowners seeking straightforward, reliable climate control without bleeding budget on premium features.
Performance metrics tell a solid story. The 97% AFUE rating on the heating side puts this furnace in the high-efficiency category, meaning minimal fuel waste on cold days. Cooling efficiency registers at 13 SEER1, which meets Energy Star standards without the premium pricing of 14 or 15 SEER units. The modulating burner and variable-speed ECM blower motor at up to 1200 CFM provide responsive comfort management. These specs translate to real savings for homeowners in mixed-climate regions.
Pros & Cons
Pros
- 97% AFUE heating efficiency reduces fuel consumption and monthly bills significantly compared to standard 80-85% furnaces
- 13 SEER cooling rating paired with R454B refrigerant meets current environmental standards while delivering solid AC performance
- Modulating burner automatically adjusts to heating demand rather than cycling on/off, improving comfort and reducing energy waste
- Variable-speed ECM blower motor reaches 1200 CFM maximum, enabling better air distribution and comfort during peak demand
- 10-year warranty with online registration provides solid protection for both heating and cooling components
- Energy Star certified system qualifies for potential rebates in many utility districts
Cons
- Single-stage compressor cannot modulate cooling output, limiting part-load efficiency compared to two-stage or variable-capacity units
- 73 dB noise level is moderately loud, potentially noticeable in quiet residential areas during compressor operation
- Requires 115V single-phase power, limiting options in some commercial or industrial applications
Who Should Buy
Best For
Homeowners replacing an old split system and wanting one reliable package for both heating and cooling, especially those in regions with balanced seasonal demand. Budget-conscious buyers who qualify for utility rebates will appreciate the Energy Star rating without paying for premium modulating compressors.
Consider Alternatives If
Anyone needing ultra-quiet operation, those in extremely hot climates requiring two-stage compressors for efficiency, or buyers seeking variable-capacity cooling systems that modulate to exact load requirements.
Installation
Installation requires standard split-system approach: furnace indoors in upflow configuration, condenser outside. The system uses 3/8 inch liquid lines and 3/4 inch suction lines with 3/4 inch insulation thickness over a maximum 50-foot run. Electrical requirements are straightforward, needing 115V single-phase 60Hz power with 16.7 to 25 amp breaker. Plastic or PVC flue venting is required for exhaust.
Warranty & Reliability
Ten-year comprehensive warranty covers both furnace and cooling components when you register online. This is standard coverage for this equipment class and provides meaningful protection against manufacturing defects. Warranty does not typically cover installation errors, refrigerant loss, or wear items like filters.
Specifications
| SKU | ACIQ-30-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 30,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 73 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 16.7 amps |
| Tonnage | 2.5 Ton |
| Valve Type | Sweat |
| Height | 22" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7424264 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow / Downflow |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions