This Goodman gas furnace and air conditioner pairing represents a practical middle-ground solution for homeowners seeking equipment upgrades without boutique pricing. At $464, you're getting a complete 2.5 ton system rather than paying separately for furnace and condenser. The upflow configuration and A-coil design work in standard residential installations, making this an accessible option for replacement projects where space constraints matter.
The 97% AFUE rating on the furnace side is genuinely impressive, meaning 97 cents of every dollar spent on natural gas converts to heat. On cooling, the 13 SEER1 efficiency handles moderate climates effectively, outputting 30,000 BTU across a maximum 1,600 CFM airflow. The modulating burner avoids the energy waste of constant on-off cycling, while the variable-speed ECM blower runs quieter at 73 dBA and adjusts to heating or cooling demands automatically.
Pros & Cons
Pros
- 97% AFUE furnace efficiency is top-tier for gas heating, significantly reducing natural gas consumption compared to 80% AFUE units
- 13 SEER cooling efficiency meets Energy Star standards, delivering reliable AC performance in moderate climates
- Modulating burner adjusts heat output in stages rather than on/off cycling, improving comfort and reducing energy waste
- Variable-speed ECM blower motor runs at optimal speeds for each season, quieter operation at 73 dBA than fixed-speed alternatives
- R454B refrigerant meets current EPA standards for newer equipment without legacy chlorine-based compounds
Cons
- Single-stage condenser means AC capacity is fixed, less flexible than two-stage units in extreme heat conditions
- 2.5 ton capacity may be undersized for homes larger than 1,800-2,000 square feet in hot climates
- Reciprocating compressor design generates more heat than scroll compressors, reducing efficiency in high ambient temperatures
Who Should Buy
Best For
Homeowners in moderate climates replacing 15-25 year old furnace and AC units should strongly consider this system. It's particularly suited for people prioritizing lower heating bills since the 97% AFUE will recoup the investment through reduced gas costs within 5-7 years.
Consider Alternatives If
Skip this model if you live in consistently hot climates above 95 degrees or need cooling capacity exceeding 30,000 BTU, as the single-stage compressor design loses efficiency under extreme heat stress.
Installation
Installation requires 115V single-phase 60Hz power with 16.7 to 25 amp breaker capacity, standard in most homes. Line sets use 3/8 inch liquid and 3/4 inch suction connections with sweat valve fittings, 50 feet maximum length. The unit measures 34.5 inches tall, 21 inches wide, and 28.75 inches deep, fitting typical furnace closets. PVC plastic exhaust flue is required.
Warranty & Reliability
Goodman provides a 10-year warranty when you complete online registration after installation. This covers manufacturing defects in compressor, heat exchanger, and major components. Registration is mandatory to activate the full period, so dealers must document this during startup. Parts labor and refrigerant are typically separate, so verify coverage specifics with your installer.
Specifications
| SKU | ACIQ-30-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 30,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 73 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 16.7 amps |
| Tonnage | 2.5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installations Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7424266 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |