Review
The 2.5-ton Goodman gas furnace and air conditioner system sits in the practical middle ground of HVAC equipment, offering Energy Star efficiency without luxury pricing. At $2,666, it competes directly with mid-tier alternatives from Lennox and Carrier. This horizontal A-coil configuration targets contractors and homeowners needing dependable capacity for homes between 2,000 and 2,500 square feet. The product carries AHRI certification (7368834), confirming matched-pair performance and eligibility for utility incentives in most markets.
Heating output reaches 80,000 BTU with 96% AFUE, meaning minimal fuel waste through the flue. The air conditioning side delivers 30,000 BTU at 13 SEER, qualifying as Energy Star certified. Its two-stage burner prevents short-cycling by modulating between high and low fire, while the variable-speed ECM blower adjusts between 0 and 1,200 CFM based on demand. R454B refrigerant handles environmental compliance. The reciprocating compressor with single-stage operation works efficiently in moderate climates but trails two-stage designs when managing partial-load situations.
Pros & Cons
Pros
- 96% AFUE furnace efficiency significantly reduces heating costs compared to 80-90% units
- 13 SEER cooling with Energy Star certification qualifies for utility rebates in many regions
- Variable-speed ECM blower motor adjusts output between 0-1200 CFM for comfort and efficiency
- Two-stage burner modulates heating to reduce short-cycling and temperature swings
- R454B refrigerant meets current EPA standards with lower environmental impact
- 10-year warranty with online registration covers parts and labor on major components
Cons
- Single-stage air conditioner compressor less efficient than two-stage units in mild weather
- 73 dB noise level slightly elevated for some homeowners concerned about outdoor unit sound
- Horizontal configuration limits placement options in homes without attic space or crawlspace access
Who Should Buy
Best For
Contractors and homeowners replacing matched heating-cooling systems in homes with attic or horizontal spaces, particularly in HVAC zones 4-6. Ideal for those wanting efficiency rebates and lower operating costs without stepping up to premium-tier systems.
Consider Alternatives If
Skip this if you need a two-stage compressor for extreme climates, prefer quiet outdoor units below 70 dB, or require vertical upflow-only configuration in tight spaces.
Installation
Horizontal placement requires attic, crawlspace, or basement ceiling clearance with at least 34.5 inches of height. The unit weighs 120 pounds, making two-person installation necessary. Suction line (3/4 inch) needs 3/4-inch foam insulation over 50 feet maximum run. Electrical demand ranges from 16.7 to 25 amps at 115V single-phase 60 Hz. Plastic or PVC exhaust flue is required. Professional installation is recommended for proper refrigerant charge and airflow balance.
Warranty & Reliability
Goodman covers parts and labor for 10 years after online registration, eliminating the need for extended service contracts on defects. This matches competitor standard warranties. Coverage includes compressor, blower motor, and heat exchanger. Registration must occur within 30 days of installation to activate full protection. Homeowners moving to new properties can sometimes transfer remaining coverage.
Specifications
| SKU | ACIQ-30-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 30,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 73 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 16.7 amps |
| Tonnage | 2.5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368834 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions