The Goodman 2.5-ton gas furnace and air conditioner system represents a practical entry-level solution for homeowners seeking reliable climate control without premium pricing. Goodman holds strong market share among contractors and rental properties, built on reputation for straightforward service and parts availability. This upflow A-coil configuration suits most residential installations where space permits vertical mounting. The system pairs a 100,000 BTU furnace with 30,000 BTU cooling capacity, handling typical single-family home loads effectively.
Performance specs reveal a competent but conventional approach. The furnace delivers 80% AFUE efficiency with two-stage burners, meaning 20% of fuel energy exits through the flue. The 14 SEER air conditioner achieves reasonable cooling efficiency through a single-stage rotary compressor operating on R410A refrigerant. Variable-speed blower operation up to 2,000 CFM provides flexible airflow for zone balancing. At 72 decibels, outdoor noise levels fall within typical range for single-stage units. Electrical requirements are modest, needing 120V single-phase with 17.1 to 25-amp breaker capacity.
Pros & Cons
Pros
- Two-stage burner on furnace reduces short cycling and improves comfort during partial-load operation
- Variable-speed blower motor delivers up to 2,000 CFM and adapts to heating and cooling demands
- R410A refrigerant meets current environmental standards without retrofit requirements
- 80% AFUE furnace efficiency is adequate for most climates and keeps installation costs lower than high-efficiency alternatives
- 10-year warranty with online registration provides reasonable protection on parts
Cons
- 14 SEER rating trails modern high-efficiency units, resulting in higher cooling costs over system lifetime
- 80% AFUE furnace wastes more heat than 95%+ AFUE models, meaningfully impacting heating bills in cold climates
- Single-stage compressor cycles on and off rather than modulating, reducing efficiency and comfort at partial loads
Who Should Buy
Best For
Homeowners replacing an aging furnace and air conditioner in mild-to-moderate climates where they plan to stay less than 10 years will appreciate the lower upfront cost. Budget-conscious buyers who prioritize affordability over energy optimization should find this system meets their baseline comfort needs.
Consider Alternatives If
Homeowners in cold climates or those planning 15+ year ownership should evaluate 95% AFUE furnaces and 16+ SEER air conditioners, as energy savings will outweigh the higher purchase price within 7-8 years.
Installation
This upflow system requires a 34.5-inch height clearance and metal exhaust flue for safe furnace venting. Line sets use standard 3/8-inch liquid line and 3/4-inch suction line with 3/4-inch insulation thickness, stocked by most supply houses. Two-stage burner setup demands proper gas line sizing and testing. Professional installation ensures correct refrigerant charging, electrical connections, and combustion analysis on the furnace.
Warranty & Reliability
Online registration unlocks a 10-year parts warranty, standard for entry-level Goodman equipment. This protects compressor, heat exchanger, and coil failures but typically excludes labor and refrigerant. Coverage depends on proper installation and routine maintenance. Registration through Goodman's website is required within 30 days of activation to validate coverage.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 30,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 72 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Tonnage | 3.5 Ton |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |