Independent Review · Updated June 2026

Goodman 2.5 Ton 14 SEER 92% 60,000 BTU Furnace & AC System - R410A Upflow

Budget-friendly 14 SEER combo with solid 92% furnace efficiency and Energy Star rating

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
Goodman 2.5 Ton 14 SEER 92% 60,000 BTU Furnace & AC System - R410A Upflow
Current Price
$732
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system hits the sweet spot for budget-conscious contractors and homeowners seeking reliable heating and cooling without premium pricing. The 92% AFUE furnace paired with 14 SEER cooling makes it an Energy Star certified choice for moderate climates where you need balanced performance year-round.

Review

The ACiQ 2.5 ton system represents practical value in today's HVAC market. At $732, this furnace and AC combo delivers solid efficiency without cutting corners on reliability. The unit features a 92% AFUE furnace paired with a 14 SEER air conditioner, both certified Energy Star compliant. ACiQ's positioning as an accessible alternative to premium manufacturers means contractors can offer effective equipment to price-sensitive customers while maintaining respectable performance benchmarks.

Performance specs tell a straightforward story. The furnace produces 30,000 BTU heating output with single-stage burner operation, while the AC side delivers matching 30,000 BTU cooling capacity using R454B refrigerant. The multi-speed blower motor reaches 1,200 CFM maximum, allowing flexible airflow adjustment. At 74 dB, noise levels remain acceptable for residential installations. The upflow configuration with right-side flue venting offers installation flexibility in typical basement and utility closet applications.

Pros & Cons

Pros

  • 92% AFUE furnace efficiency beats standard 80% models by significant margin on heating bills
  • 14 SEER cooling rating with R454B refrigerant meets modern environmental standards and Energy Star requirements
  • Multi-speed blower motor allows better temperature control and quieter operation at part load
  • 30,000 BTU heating and cooling capacity handles 2.5 ton residential applications effectively
  • Affordable $732 price point makes system accessible for budget-conscious replacements

Cons

  • Single-stage burner and single-stage compressor limit efficiency gains at partial loads compared to modulating units
  • 74 dB noise level is moderate, higher than premium models with variable-speed compressors
  • Limited to 208/230V single phase power, requiring standard electrical service

Who Should Buy

Best For

Contractors and homeowners replacing aging 80% AFUE systems in moderate climates where heating and cooling demands are relatively balanced. This system works well for ranch homes and smaller two-story properties where 2.5 ton capacity meets actual load requirements.

Consider Alternatives If

Homeowners in extreme climates requiring modulating efficiency, those with three-phase power available, or buyers prioritizing quietest operation should explore higher-tier systems.

Goodman 2.5 Ton 14 SEER 92% 60,000 BTU Furnace & A
$732
Buy at HVACDirect →

Installation

Installation requires 208/230V single-phase 60Hz electrical service with breaker sizing between 18.7 and 30 amps. The upflow/horizontal orientation works in standard furnace closets and basements. Plastic PVC exhaust flue venting simplifies ductwork compared to metal alternatives. The A-coil design pairs efficiently with standard ductwork. Suction line insulation of 3/4 inch thickness meets code requirements. Pre-charged refrigerant lines (50 feet included) reduce field labor time significantly.

Warranty & Reliability

The 10-year warranty with online registration provides solid protection for components and workmanship. Registration requirement is straightforward and typically completed during installation. Coverage includes the scroll compressor and heat exchanger, addressing the costliest failure points. This warranty term matches industry standards for mid-tier equipment and exceeds many budget alternatives.

Specifications

SKUACIQ-30-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU30,000
Heating BTU30,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE92%
Blower MotorMulti Speed
Maximum CFM1200
ConfigurationUpflow / Downflow
Flue LocationRight
Burner StagesSingle
Fuel TypeGas
Height30"
Width17.5"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ReplacesGSZ140311
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size18.7 amps
Tonnage3 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

How does the 92% AFUE furnace compare to standard units on heating costs? +
A 92% AFUE furnace converts 92 cents of every fuel dollar to heat, versus 80 cents for standard 80% AFUE models. For homes burning 1,000 therms annually, this 12% efficiency gap saves approximately $150 to $180 yearly on natural gas costs, paying for efficiency premiums within 3 to 5 years.
Can this system work with my existing ductwork from a 3 ton unit? +
Yes, the 2.5 ton capacity with 1,200 CFM maximum airflow integrates into existing 3 ton ductwork without issues. The multi-speed blower adjusts to system conditions. Verify duct sizing matches 2.5 ton design parameters, though oversized ducts from previous 3 ton systems cause minimal problems.
Is 14 SEER cooling adequate for hot climates? +
14 SEER rating suits moderate climates but falls short in sustained heat regions like Arizona or Florida. Systems rated 16 SEER or higher handle continuous high-temperature operation more efficiently. For climates averaging under 90 degrees peak summer temperatures, 14 SEER provides acceptable cooling performance.
How does this compare to Goodman or Lennox equivalents? +
ACiQ positions itself as value-focused beneath Goodman's premium lines while matching core specifications. A Goodman 14 SEER unit costs 20 to 30% more. Lennox entry-level models offer similar pricing but often feature lower AFUE ratings. ACiQ delivers competitive efficiency per dollar spent.
What does the 10-year warranty actually cover? +
Coverage includes compressor, heat exchanger, and component defects. Registration is required within 60 days of installation. Labor costs beyond the first year are homeowner responsibility. This covers manufacturing defects but excludes wear items, maintenance neglect, and improper installation.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.