The Goodman 2.5-ton gas furnace and air conditioner system represents a practical middle-ground option for homeowners balancing equipment cost against operating efficiency. Goodman has built a solid reputation for reliable, unpretentious equipment across residential HVAC applications. This upflow configuration suits homes with basement or crawl space furnace placement. At this price point and efficiency tier, the system competes directly with other mainstream brands targeting contractors and budget-conscious homeowners who want better-than-baseline performance without premium costs.
The furnace delivers 100,000 BTU of heating capacity with 92% AFUE, meaning nearly all fuel converts to usable heat. The air conditioner side produces 30,000 BTU of cooling capacity with 14 SEER efficiency rating. The multi-speed blower motor adjusts to 2000 CFM maximum, allowing quieter operation at lower speeds during mild weather. Electrical requirements are modest at 208/230V single-phase 60 Hz with 17.1 to 25 amp breaker sizing, fitting standard residential panels without upgrades.
Pros & Cons
Pros
- 92% AFUE furnace efficiency exceeds federal minimum standards by 10-12 percentage points
- 14 SEER cooling rating qualifies as good efficiency for 2.5-ton residential systems
- Multi-speed blower motor allows variable airflow, improving comfort and reducing runtime
- PVC flue compatibility simplifies installation in many retrofit scenarios
- 10-year warranty with online registration provides solid long-term protection
Cons
- Single-stage burner and compressor mean less granular efficiency control than two-stage alternatives
- 72 dB noise level is moderately loud, especially during heating cycles
- Not Energy Star certified, missing eligibility for some utility rebates
- Specs show conflicting tonnage (2.5 ton in title but 3.5 ton in specs), creating confusion
Who Should Buy
Best For
Homeowners in mixed climates (heating and cooling seasons of similar length) who prioritize straightforward reliability and solid baseline efficiency over premium performance. Contractors installing systems in homes with standard ductwork and existing 208/230V single-phase electrical service will appreciate the uncomplicated installation path.
Consider Alternatives If
Buyers in hot climates seeking maximum cooling efficiency, homes with noise sensitivity issues, or anyone expecting Energy Star rebates should look at alternatives with two-stage compressors or higher SEER ratings.
Installation
Installation requires 208/230V single-phase power and standard ductwork compatible with 2000 CFM maximum airflow. The unit measures 26 inches tall by 21 inches wide and deep, fitting standard utility closets and mechanical rooms. PVC flue venting is permitted, simplifying routing in many homes. The 3/8-inch liquid line and 3/4-inch suction line are standard sizes, and 50 feet of line set length accommodates most residential layouts. Professional installation is strongly recommended.
Warranty & Reliability
Goodman provides a 10-year warranty when you register the system online after purchase. This covers parts and labor through the complete warranty period, offering solid peace of mind for residential buyers. Registration is simple and often completed during commissioning. Some components may have shorter coverage periods, so review documentation carefully. The 10-year term matches industry standards for mid-tier equipment.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 30,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A or R22 |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 72 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 92% |
| Blower Motor | Multi Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Height | 26" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Tonnage | 3.5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |