Review
The Goodman 2.5 ton horizontal system combines a 96% AFUE furnace with a 13 SEER air conditioner into a complete package solution. This pairing targets the middle market, where contractors and homeowners want respectable efficiency ratings without the premium pricing of variable-capacity or inverter-driven equipment. The system qualifies for Energy Star certification, and Goodman's established parts network makes service accessible across most regions. The horizontal A-coil configuration provides flexibility for attic and basement installations.
Heating performance delivers 60,000 BTU input with two-stage burner capability, allowing the furnace to modulate between high fire and low fire for better comfort and efficiency. The variable-speed ECM blower reaches 1200 CFM maximum airflow and adjusts automatically based on heating demand. Cooling output registers at 30,000 BTU, which is notably lower than the heating capacity. The single-stage compressor using R454B refrigerant operates at 73 dB and suits applications where moderate cooling load matches the tonnage.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means minimal heating fuel waste, especially valuable in colder climates with extended heating seasons
- 13 SEER cooling rating and Energy Star certification provide good seasonal efficiency across both heating and cooling modes
- Variable-speed ECM blower motor with 1200 CFM capacity allows precise airflow management and better humidity control
- Two-stage burner on furnace enables part-load operation, reducing short-cycling and improving comfort
- Lifetime heat exchanger warranty provides substantial peace of mind on the most expensive furnace component
- Horizontal/upflow A-coil configuration offers flexible installation in basements, crawlspaces, and attics
Cons
- Single-stage compressor on the air conditioner lacks variable capacity, making it less efficient at part-load cooling conditions
- 73 dB noise level is moderately loud, potentially noticeable during compressor operation in quiet homes
- 30,000 BTU cooling capacity feels undersized relative to the 60,000 BTU heating output, suggesting this pairs best with existing equipment rather than new construction
Who Should Buy
Best For
Contractors replacing failed furnace-AC combinations in homes where existing ductwork and infrastructure are compatible, and homeowners in mixed-climate regions who need both solid heating and cooling performance without spending on premium modulating equipment.
Consider Alternatives If
Buyers in hot climates prioritizing cooling efficiency should consider higher SEER equipment, and those seeking whisper-quiet operation should evaluate quieter compressor designs.
Installation
Installation requires 115V, 1-phase power with 16.7 to 25-amp breaker sizing. Refrigerant lines use 3/8 inch liquid and 3/4 inch suction connections with sweat-type valves. The unit weighs 120 lbs and measures 34.5 inches tall by 17.5 inches wide by 28.75 inches deep in horizontal orientation. PVC or plastic exhaust flue is required. Suction line insulation is pre-installed at 3/4 inch thickness with 50 feet of included length.
Warranty & Reliability
Goodman provides a lifetime warranty on the heat exchanger and 10 years parts coverage with online registration. The lifetime heat exchanger warranty is industry-leading and reflects confidence in the core component. Registration is straightforward and extends parts coverage significantly, making this an important first step after installation.
Specifications
| SKU | ACIQ-30-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 30,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 73 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 16.7 amps |
| Tonnage | 2.5 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368833 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |