Review
This Goodman 2.5-ton system represents solid mid-market equipment for residential HVAC applications. The combination of a 60,000 BTU 96% AFUE furnace paired with a 29,000 BTU cooling coil addresses moderate heating and cooling loads in mixed-climate homes. Goodman's reputation for straightforward engineering and field reliability makes this an accessible choice for contractors and budget-conscious homeowners alike. The unit ships from Online Supply with full manufacturer documentation and rebate eligibility.
Performance metrics show a well-balanced heating emphasis. The furnace delivers exceptional efficiency at 96% AFUE with two-stage burner technology that runs at reduced capacity approximately 80% of the heating season. The air conditioner achieves 16 SEER1 efficiency using a scroll compressor and R410A refrigerant. Variable-speed ECM blower delivery ranges from 300 to 1200 CFM, enabling precise air distribution. These specifications translate to meaningful utility savings compared to single-stage, fixed-capacity predecessors, particularly in shoulder seasons.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs by approximately 4-6% versus standard 90% units
- Variable-speed ECM blower motor adjusts output from 300 to 1200 CFM, improving comfort and reducing energy waste during partial-load operation
- Two-stage burner allows efficient low-fire operation 80% of the heating season, minimizing short cycling and improving indoor comfort
- ENERGY STAR certified with 16 SEER1 cooling efficiency, qualifying for utility rebates in many regions
- Lifetime heat exchanger warranty demonstrates manufacturer confidence in furnace longevity
Cons
- Single-stage air conditioner compressor limits partial-load efficiency during mild weather cooling cycles
- 29,000 cooling BTU falls slightly short of 2.5-ton capacity specification, creating a minor mismatch in system design
- 71.5 dB noise level is audible during operation, potentially noticeable in quiet homes or bedrooms adjacent to furnace location
- Requires PVC exhaust flue, limiting installation flexibility in older homes with masonry chimneys
Who Should Buy
Best For
Homeowners replacing aging furnace-AC systems in climates requiring consistent heating and occasional cooling should prioritize this unit. Contractors installing multi-unit residential projects benefit from the straightforward upflow/horizontal configuration, proven Goodman reliability, and attractive warranty package.
Consider Alternatives If
Buyers in hot climates needing aggressive cooling performance or those seeking variable-capacity compressors for maximum efficiency should explore two-stage air conditioning options instead.
Installation
Installation requires standard 115V, 60 Hz single-phase electrical service with 17.1 to 25-amp breaker capacity, making it compatible with most residential panels. The horizontal A-coil configuration suits basements, attics, or crawlspaces with height constraints. PVC exhaust flue installation is mandatory, requiring new ductwork if existing masonry chimney is present. Line set connections use standard 3/8-inch liquid and 7/8-inch suction fittings with 3/4-inch insulation, allowing reuse of existing refrigerant lines where clearances permit.
Warranty & Reliability
Goodman's lifetime heat exchanger warranty covers material defects indefinitely, addressing the most expensive component failure risk. The 10-year parts warranty applies to compressor, blower, and controls when registered online within 30 days of installation. This tiered approach is competitive for the price point but requires documented professional installation to validate coverage, making contractor selection important.
Specifications
| SKU | LS38783850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 29,000 |
| Heating BTU | 60,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Tonnage | 3 Ton |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| AHRI Certificate Number | 7368833 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions