Review
The Goodman 2.5-ton upflow system represents solid mid-range performance for homeowners balancing efficiency and cost. Manufactured by Online Supply, this unit combines a 96% AFUE furnace with a 16 SEER2 air conditioner in one package. Energy Star certification appeals to conscious buyers and opens eligibility for utility rebates. The variable-speed ECM blower motor distinguishes this system from basic single-speed alternatives, promising more consistent temperature control throughout the heating season.
Performance specs show 40,000 BTU heating capacity with two-stage burner operation and 29,000 BTU cooling output from a scroll compressor. The 1,200 CFM maximum airflow handles the tonnage appropriately without oversizing ducting. At 71.5 dBA, expect noticeable sound during operation, typical for scroll compressor systems at this price point. The A-coil configuration with 3/4-inch suction line insulation minimizes efficiency losses between indoor and outdoor units during the cooling cycle.
Pros & Cons
Pros
- 96% AFUE furnace efficiency beats most mid-range competitors and reduces heating costs significantly
- 16 SEER2 cooling efficiency qualifies for Energy Star and many utility rebates
- Variable-speed ECM blower motor delivers 1,200 CFM maximum airflow with better temperature consistency
- Two-stage burner and single-stage compressor provide balanced heating and cooling without excessive cycling
- PVC plastic exhaust flue requirement simplifies installation compared to metal vent systems
- 10-year warranty with online registration provides solid protection and peace of mind
Cons
- 71.5 dBA noise level is moderately loud, noticeable during operation in quiet homes
- Single-stage compressor means less sophisticated cooling modulation than variable-capacity units
- Spec sheet shows conflicting tonnage claims (title says 2.5 ton, specs list 3 ton) requiring clarification before purchase
Who Should Buy
Best For
Homeowners in moderate climates who prioritize heating efficiency and want Energy Star certification without paying for premium variable-capacity cooling. Contractors installing in upflow configurations appreciate the straightforward PVC vent requirements and reliable Goodman components.
Consider Alternatives If
Buyers in extreme climates needing maximum efficiency tiers, or those sensitive to equipment noise should explore quieter and higher-SEER alternatives.
Installation
Installation favors upflow applications with plastic PVC exhaust flue requirements, reducing material costs compared to metal vent systems. The 115V single-phase 60Hz electrical specification works with standard residential circuits rated for 17.1 to 25 amperes. Unit dimensions of 26 inches tall by 17.5 inches wide by 21 inches deep fit most furnace closets and basement installations. Pre-charged refrigerant lines at 50 feet simplify field connections for certified technicians.
Warranty & Reliability
The 10-year comprehensive warranty applies with free online registration through Goodman. Coverage includes parts and compressor protection, standard for residential systems at this tier. Registration ensures access to warranty claim support and extends eligibility for certain component replacements. Extended warranties from retailers may offer additional protection beyond the manufacturer's baseline coverage.
Specifications
| SKU | LS38783850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 29,000 |
| Heating BTU | 40,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Tonnage | 3 Ton |
| Height | 26" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368841 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |