Review
The ACiQ 2-ton split system represents Goodman's entry-level offering for homeowners balancing budget constraints against efficiency gains. At $2,466, this unit delivers solid performance in replacement scenarios where the existing infrastructure supports downflow installation. The combination of a 60,000 BTU furnace and 24,000 BTU air conditioner targets small homes and condos in moderate climates. Its Energy Star certification signals compliance with current federal standards, making it a practical choice for contractors and DIY replacements.
Performance metrics justify the mid-market positioning. The furnace's 96% AFUE efficiency ranks above basic 80-92% models, translating to measurable annual savings on natural gas or propane heating. On the cooling side, 13 SEER1 meets Energy Star thresholds but represents baseline efficiency rather than premium performance. The variable-speed ECM blower adjusts from idle to 1,200 CFM, reducing compressor cycling on mild days. Two-stage burner control prevents the temperature swings common in single-stage furnaces, though the single-stage compressor cannot similarly modulate cooling.
Pros & Cons
Pros
- 96% AFUE furnace efficiency exceeds most budget alternatives, saving approximately 15-20% on heating costs versus 80% units
- 13 SEER rating is Energy Star certified, meeting federal minimum standards and qualifying for some utility rebates
- Variable speed ECM blower motor automatically adjusts to 1200 CFM maximum, improving comfort and reducing runtime electricity use
- Two-stage burner provides precise heating control and less on-off cycling compared to single-stage models
- Downflow A-coil configuration works in tight attic or closet installations where space is constrained
Cons
- Single-stage air conditioner compressor cannot modulate capacity, cycling on-off fully rather than ramping down on mild days
- 75 dBA noise level is audible from adjoining rooms, louder than premium two-stage units which run quieter at part load
- R454B refrigerant requires technician familiarity; not all older contractors stock proper oil and charging equipment
Who Should Buy
Best For
Homeowners in moderate climates needing 2-ton capacity replacement looking for strong heating efficiency without premium pricing. Contractors purchasing complete systems for spec builds in regions without extreme summer cooling demands.
Consider Alternatives If
Anyone in hot, humid climates or with high cooling demand should consider 14+ SEER units or two-stage compressors that modulate efficiency during partial-load hours.
Installation
This downflow A-coil unit requires 115V single-phase power with 10.3 to 15-amp breaker sizing, typical for residential installations. Dimensions of 34.5 inches tall, 17.5 inches wide, and 28.75 inches deep fit standard closet or attic spaces. Sweat valve connections and 3/8-inch liquid line plus 3/4-inch suction line interface with standard copper runs. PVC/plastic exhaust flue requirement simplifies venting versus metal pipe in condensing furnaces. Most HVAC technicians complete installation in 4-6 hours on straightforward changeouts.
Warranty & Reliability
ACiQ backs this unit with 10 years parts coverage upon online registration, matching or exceeding typical Goodman warranty terms. Registration is straightforward and crucial, as unregistered units default to 1-year coverage. The 10-year window covers compressor failure, blower motor defects, and heat exchanger cracks. Labor costs and refrigerant charges fall outside warranty scope. This duration protects against premature component failure but doesn't cover wear items like capacitors or contacts.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368838 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.