Review
The ACiQ 2 Ton horizontal furnace and air conditioning system bridges the gap between budget equipment and premium options, targeting contractors and homeowners seeking reliable efficiency in space-constrained installations. Built on Goodman's platform, this unit combines an 80,000 BTU furnace with 24,000 BTU cooling capacity in a horizontal configuration measuring just 21 inches tall by 26 inches deep. The SKU ACIQ-24-EHPD-UPG replaces older GSX130242 models and includes a rebate program, making it accessible for budget-conscious upgrades.
Performance metrics reveal solid engineering for the price point. The furnace delivers 96% AFUE efficiency, meaning 96 cents of every heating dollar converts to home warmth, substantially beating 80% baseline models common in older homes. Cooling operates at 13 SEER1 with R454B refrigerant, a modern choice avoiding R410A supply constraints. The variable-speed ECM blower adjusts CFM from 0 to 1600 based on demand, reducing energy waste during partial-load operation. Two-stage burner switching provides staging comfort, while the rotary compressor handles 208/230V single-phase power through a 10-15 amp breaker.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly compared to 80-85% baseline units
- 13 SEER cooling with R454B refrigerant meets current environmental standards and avoids R410A phase-down concerns
- Variable-speed ECM blower motor optimizes comfort and reduces runtime electricity draw
- PVC exhaust flue simplifies installation in tight spaces without expensive rigid metal ducting
- Two-stage burner provides better comfort control and efficiency at partial heating loads
- 10-year warranty with online registration offers solid peace of mind coverage
Cons
- 3.5 ton outdoor unit mismatch with stated 2 ton capacity creates specification confusion that requires clarification before purchase
- Single-stage condenser limits cooling efficiency compared to two-stage alternatives at the same SEER rating
- 75 dB noise level runs slightly louder than premium models, noticeable in bedrooms during operation
Who Should Buy
Best For
Contractors replacing failed systems in homes with attic or basement installations need compact horizontal configurations. Homeowners in moderate climates seeking reliable efficiency improvements without premium pricing will find good value here.
Consider Alternatives If
Skip this if you need two-stage cooling for enhanced efficiency in hot climates, or if you require ultra-quiet operation for bedroom proximity applications.
Installation
Horizontal installation suits attics and crawlspaces where traditional vertical furnaces don't fit. PVC plastic exhaust flue requirements simplify venting compared to expensive metal ductwork, though installers must slope lines properly for condensate management. Pre-charged refrigerant lines up to 50 feet reduce field work. Sweat connections on 3/8 inch liquid lines and 3/4 inch suction lines require certified technician-level soldering. Weight of 120 pounds demands proper bracing in horizontal mounting.
Warranty & Reliability
Ten-year comprehensive parts warranty applies upon online registration, covering compressor, furnace heat exchanger, and components. This matches industry standard midrange coverage without lifetime options. Registration is essential, as non-registered units typically receive shorter 5-year protection. Labor and refrigerant charges fall outside warranty scope, which is typical across all manufacturers.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7368843 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Horizontal |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 21" |
| Width | 21.125" |
| Depth | 26" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Replaces | GSX130242 |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 3.5 Ton |
| Valve Type | Sweat |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |