The ACiQ 2-ton system pairs a Goodman gas furnace with an air conditioning condenser, covering both heating and cooling needs in a single equipment bundle. This is a practical choice for homeowners replacing older split systems or upgrading from basic equipment. The combination emphasizes reliability and straightforward installation rather than cutting-edge technology, making it accessible to contractors and homeowners alike.
The furnace delivers impressive 96% AFUE efficiency with two heating stages and a 30,000 BTU output, meaning it extracts virtually all heat from combustion before venting. The 2-ton AC condenser produces 24,000 BTU of cooling at 13 SEER1 with a rotary compressor and sweat connections. An ECM blower motor tops out at 1,200 CFM, automatically adjusting speeds for better temperature control. PVC flue compatibility keeps installation costs lower on most homes.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means lower heating bills and minimal heat loss up the flue, translating to real savings in winter months
- 13 SEER1 rating on the condenser meets Energy Star standards and provides respectable cooling efficiency for a non-variable system
- ECM multi-speed blower motor maximizes airflow distribution at 1,200 CFM while reducing energy consumption compared to single-speed alternatives
- Two-stage burner allows the furnace to run at lower capacity during mild weather, improving comfort and reducing short-cycling
- R454B refrigerant is low-GWP and future-proof against EPA regulations, plus 10-year warranty with online registration provides solid coverage
Cons
- Single-stage compressor on the AC condenser cannot modulate capacity, so cooling performance is all-or-nothing without the comfort advantages of variable-speed systems
- 13 SEER1 is good but not exceptional, trailing newer variable-speed units rated 16+ SEER2, so energy savings over time will lag premium competitors
- 75 dB noise level during AC operation is noticeably louder than quieter condenser models, which may be a concern for noise-sensitive properties
Who Should Buy
Best For
Homeowners in moderate climates replacing 10+ year old systems who value heating efficiency and want reliable cooling without premium pricing. This setup works well for those willing to accept standard efficiency ratings in exchange for lower upfront costs and solid long-term performance.
Consider Alternatives If
Buyers in hot climates needing maximum cooling capacity should consider higher SEER models, and those in extreme cold climates may benefit from higher-stage heating systems instead.
Installation
The upflow configuration and A-coil design fit standard furnace closets and attic spaces without major ductwork changes. Refrigerant lines measure 3/8 inch liquid and 3/4 inch suction with 50 feet of supplied insulation, covering typical residential runs. The system requires a 10.3 to 15 amp breaker and standard 115V single-phase power. Most HVAC contractors can handle installation in 4 to 6 hours with basic tools.
Warranty & Reliability
ACiQ backs this system with a 10-year parts warranty that activates through online registration. This extends coverage to most components including the compressor and heat exchanger. Warranty terms are standard for equipment in this price range. Homeowners should complete registration promptly and keep service records to ensure coverage validity.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 30,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 2 Ton |
| Valve Type | Sweat |
| Height | 18" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi-Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Gas |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |