Review
The ACiQ 2 ton system, model ACIQ-24-EHPD-UPG, pairs a Goodman gas furnace with an air conditioner condenser in a horizontal downflow configuration. This is a replacement for the older GSX130242 unit and targets homeowners who heat with propane or natural gas while needing basic cooling. The combination approach simplifies installation compared to sourcing separate furnace and condenser units from different manufacturers.
Efficiency is the real selling point here. The furnace delivers 97% AFUE with modulating burner stages that adjust heat output continuously instead of cycling on and off, reducing energy waste during partial load operation. The 80,000 BTU heating capacity handles 2 ton cooling duty, paired with a 24,000 BTU air conditioner rated at 13 SEER1. The variable speed ECM blower adjusts to 1200 CFM maximum, meaning it ramps down on mild days and runs only as hard as needed.
Pros & Cons
Pros
- 97% AFUE furnace efficiency is among the highest available for gas furnaces, reducing heating fuel consumption significantly
- Modulating burner stages adjust heat output precisely, avoiding the energy waste of constant on-off cycling
- Variable speed ECM blower matches airflow to demand, improving comfort and lowering fan energy use
- 13 SEER1 air conditioning with R454B refrigerant meets current environmental standards and Energy Star certification
- PVC exhaust compatibility simplifies venting in retrofit situations where traditional metal flues aren't practical
- 10 year warranty with online registration provides solid protection for parts and manufacturing defects
Cons
- 3 ton cooling capacity on what's labeled as a 2 ton system creates spec confusion and potential oversizing for smaller homes
- Single stage condenser limits cooling efficiency at partial load conditions compared to two stage units
- 75 dB noise level is louder than high efficiency two stage outdoor units, noticeable during operation
- Requires proper refrigerant line sizing, 3/8 inch liquid and 3/4 inch suction with 3/4 inch insulation thickness
Who Should Buy
Best For
Contractors and homeowners in northern climates where winter heating accounts for 60 percent or more of annual HVAC energy use will see real ROI from the 97% AFUE rating. This system also suits properties using propane in areas where natural gas lines aren't available.
Consider Alternatives If
Cooling-dominant markets in the South and Southwest should look at units with two stage compressors or higher SEER ratings for better part load efficiency, since this single stage design won't match their usage patterns.
Installation
Installation requires standard HVAC copper line work with 3/8 inch liquid and 3/4 inch suction lines, both insulated to 3/4 inch thickness. The horizontal A-coil configuration fits attic or basement installations where downflow discharge is acceptable. PVC venting to the exterior simplifies flue routing in tight spaces. Electrical demand is minimal at 115V single phase 60 Hz, requiring a 10.3 to 15 amp breaker.
Warranty & Reliability
ACiQ provides a 10 year parts and labor warranty when you register online after purchase. This is a solid mid-tier protection that covers manufacturing defects and component failures during the critical first decade. Registration is simple and typically extends coverage that Goodman's base warranty might otherwise limit to 5 years.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7424270 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Flue Location | Right |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.