Review
The Goodman 2-ton horizontal system combines a gas furnace and air conditioner into one integrated package, addressing the practical needs of contractors managing budget-conscious retrofit jobs. This ACiQ-branded unit delivers 80,000 BTU heating and 24,000 BTU cooling, fitting homes that previously relied on single-stage equipment. The modulating furnace burner and variable-speed blower position this system as a mid-tier efficiency solution, balancing operational costs against upfront installation investment.
Performance metrics tell a compelling story for heating efficiency. The 97% AFUE rating nearly captures all fuel energy for space heating, translating to measurably lower gas bills compared to 80-85% AFUE units still operating in many homes. Cooling delivers 13 SEER1 efficiency using R454B refrigerant, meeting current environmental standards. The variable-speed ECM blower motor operates at 1,200 CFM maximum, modulating airflow based on demand rather than running at constant speed, reducing parasitic electricity draw during part-load conditions.
Pros & Cons
Pros
- 97% AFUE furnace efficiency minimizes fuel waste and heating costs year-round
- Modulating burner adjusts output smoothly rather than cycling on and off, improving comfort
- Variable-speed ECM blower motor reduces electricity consumption compared to fixed-speed alternatives
- 13 SEER cooling meets Energy Star standards with R454B low-GWP refrigerant
- 10-year warranty with online registration provides solid long-term protection
- 3-ton capacity handles most residential applications without oversizing issues
Cons
- 13 SEER is respectable but falls behind 16+ SEER units available at higher price points
- Single-stage condenser limits modulation on cooling side, reducing efficiency gains during partial-load operation
- 75 dB noise level is acceptable but louder than premium variable-capacity systems
Who Should Buy
Best For
Contractors installing replacement systems in homes with existing 2-3 ton ductwork, and homeowners seeking balanced efficiency and affordability without premium pricing. This unit works particularly well for regions with moderate cooling demands and consistent heating seasons.
Consider Alternatives If
Anyone in hot climates prioritizing minimum cooling runtime should look at higher SEER equipment, and builders seeking variable-capacity cooling should compare to two-stage or inverter-drive systems.
Installation
Installation requires standard sheet metal connections for ductwork and refrigerant lines: 3/4 inch suction line and 3/8 inch liquid line with sweat valve connections. The horizontal A-coil configuration fits tight attic spaces while the 34.5 inch height accommodates typical joist spacing. Plastic PVC exhaust piping keeps installation costs manageable. Field technicians should confirm local electrical codes support the 115V single-phase requirement with 10.3 to 15 amp breaker sizing.
Warranty & Reliability
Goodman backs this system with a 10-year parts warranty activated through online registration, a reasonable timeframe for mid-tier equipment. Coverage protects against manufacturing defects in the compressor, heat exchanger, and electrical components. Registration is straightforward and registration proof provides documentation valuable if component replacement becomes necessary during the coverage window.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installations Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7424265 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |