Review
The Goodman 2 Ton 14 SEER furnace and air conditioner system represents a middle-ground choice for residential HVAC replacement. Positioned between stripped-down baseline units and premium high-efficiency systems, this upflow configuration delivers respectable performance for typical single-family homes. The combination of 92% AFUE heating and 14 SEER cooling addresses both winter and summer efficiency concerns without aggressive pricing that limits accessibility for budget-conscious homeowners and contractors.
Performance metrics tell the practical story here. The furnace delivers 100,000 BTU heating output through a single-stage burner, while the 2-ton condenser produces 24,000 BTU cooling capacity using R410A or R22 refrigerant. The multi-speed blower motor tops out at 2,000 CFM, supporting flexible ducting strategies. These specifications work well for homes averaging 1,200 to 2,000 square feet, where oversizing penalties don't justify premium equipment investment. The 71 dBA noise level remains reasonable for equipment operating from a basement or utility closet.
Pros & Cons
Pros
- 92% AFUE furnace efficiency beats many competitors in the budget tier, reducing heating costs meaningfully
- 14 SEER cooling efficiency is solid for entry-level two-ton units, exceeding baseline SEER 13 standards
- Multi-speed blower motor improves comfort by reducing temperature swings and cycling noise at part load
- Upflow/horizontal configuration with plastic PVC exhaust simplifies installation in standard residential basements
- 100,000 BTU heating output matches typical residential heating loads without oversizing penalties
Cons
- Single-stage burner and compressor mean less efficiency at partial loads during moderate weather
- No ENERGY STAR certification, missing potential utility rebate programs available to eligible homeowners
- 71 dBA noise level is acceptable but louder than high-efficiency variable-speed alternatives
Who Should Buy
Best For
Homeowners with 2-3 ton cooling loads seeking straightforward replacement systems in existing homes with 208/230V electrical service. Contractors managing cost-sensitive retrofits where higher SEER/AFUE ratings justify modest price increases over baseline units.
Consider Alternatives If
Buyers prioritizing maximum efficiency should explore variable-speed options, and anyone unable to accommodate 208/230V single-phase power should look elsewhere.
Installation
Installation favors standard residential applications. The upflow 26 by 21 by 21 inch footprint fits most utility closets and basements without major modifications. PVC plastic exhaust piping reduces installation complexity compared to metallic alternatives. However, you'll need 208/230V single-phase 60 Hz electrical service with breaker capacity between 14.3 and 25 amps. Field technicians should verify existing ductwork compatibility before proceeding, particularly for homes with undersized return air plenums.
Warranty & Reliability
Goodman backs this system with a 10-year parts warranty, conditional on online registration. This timeframe covers most component failures during the critical early ownership period. The warranty is straightforward without surprising limitations, though coverage excludes wear items like air filters. Registration is essential since many retailers won't honor claims without completion of this step at time of purchase or immediately after installation.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 24,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A or R22 |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 92% |
| Blower Motor | Multi Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Height | 26" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 14.3 amps |
| Tonnage | 3.5 Ton |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.