Review
The 2-ton Goodman gas furnace and air conditioner system represents a balanced approach to whole-home comfort. Built on Goodman's reputation for durability, this horizontal-configuration unit combines proven components with modern efficiency standards. The system delivers 60,000 BTU of heating capacity and 24,000 BTU of cooling output, positioning it as a mid-range solution for residential properties. Its Energy Star certification and strong efficiency metrics make it competitive in the mid-tier HVAC market where contractors and homeowners seek reliability without premium costs.
Performance metrics are genuinely strong across both heating and cooling. The furnace achieves 96% AFUE, meaning 96 cents of every heating dollar translates into home warmth, with minimal energy waste up the flue. The air conditioner delivers 14 SEER1 efficiency, down from the previous SEER2 metric but still respectable for standard residential duty. The two-stage burner in the furnace runs at lower fire initially, reducing short cycling and delivering quieter, more even heating. Meanwhile, the variable-speed ECM blower adjusts to demand, keeping operation noise at 71 dBA while maintaining maximum 1,200 CFM airflow capability.
Pros & Cons
Pros
- Exceptional 96% AFUE furnace efficiency reduces natural gas or propane consumption significantly
- 14 SEER1 cooling efficiency qualifies as Energy Star certified, lowering summer cooling costs
- Two-stage furnace burner allows modulation for better comfort and reduced utility bills
- Variable-speed ECM blower motor optimizes airflow and reduces operation noise to 71 dBA
- Lifetime warranty on heat exchanger provides long-term peace of mind against catastrophic failure
- R454B refrigerant and plastic PVC exhaust capability simplifies installation in modern homes
Cons
- Single-stage cooling compressor cannot modulate capacity, resulting in less precise temperature control than two-stage units
- 3-ton cooling capacity exceeds the 2-ton specification, creating potential oversizing issues in smaller spaces
- 10-year parts warranty requires online registration, which some homeowners may overlook
Who Should Buy
Best For
Homeowners in mixed climates who need reliable dual-fuel capability and want measurable energy savings without premium pricing. This system works well for houses with moderate square footage and stable heating and cooling demands.
Consider Alternatives If
Anyone requiring variable-capacity cooling in hot, humid climates should consider two-stage units. Those without internet access or reluctant to register warranties should explore alternatives with simpler coverage.
Installation
Installation requires standard HVAC knowledge and tools. The unit ships at 120 pounds and measures 34.5 inches tall by 17.5 inches wide by 28.75 inches deep, fitting most horizontal attic or basement installations. Refrigerant lines use 3/8-inch liquid and 3/4-inch suction connections with 3/4-inch insulation thickness. Electrical demands are moderate, needing 115V single-phase 60Hz service with 14.3 to 25-amp breaker sizing. The plastic PVC exhaust requirement simplifies venting compared to older metal flue systems.
Warranty & Reliability
Goodman provides a lifetime warranty on the heat exchanger, protecting against failure of the furnace's core component. Parts coverage extends 10 years with online registration, which is standard industry practice. This two-tier approach means catastrophic heating failures are covered indefinitely, while replacement compressors or boards require coverage within the decade. Registration is essential to activate benefits, so homeowners must complete this step immediately after installation.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 14.3 amps |
| Tonnage | 3 Ton |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| AHRI Certificate Number | 7368833 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions