The Goodman 2-ton gas furnace and air conditioner system represents a practical middle ground for homeowners seeking reliable year-round comfort. This upflow, A-coil configuration fits standard installations where heating demands typically exceed cooling needs. With 60,000 BTU heating capacity and 24,000 BTU cooling output, it addresses modest residential requirements without oversizing. The combination of a 96% AFUE furnace with a 13 SEER condenser reflects Goodman's reputation for building durable, efficient equipment at accessible price points.
The furnace delivers impressive heating efficiency at 96% AFUE, converting nearly all fuel to usable heat and earning Energy Star certification. The two-stage burner modulates between high and low output, reducing short-cycling and temperature swings. On the cooling side, the 13 SEER rating uses R454B refrigerant and maintains single-stage compressor operation. This means full-capacity cooling even during mild days, which trades efficiency flexibility for straightforward reliability. Maximum airflow reaches 1200 CFM via the multi-speed ECM blower, enabling temperature distribution across typical home sizes.
Pros & Cons
Pros
- 96% AFUE furnace efficiency significantly reduces winter heating costs compared to 80-90% models
- 13 SEER condenser meets Energy Star requirements with R454B refrigerant
- Two-stage burner enables modulating heat output for better comfort and efficiency
- Multi-speed ECM blower motor adapts airflow automatically for quieter operation and even temperatures
- Lifetime heat exchanger warranty plus 10 years parts coverage with online registration
Cons
- 13 SEER is competent but not premium, cooling efficiency lags higher-tier systems by 2-3 SEER points
- Single-stage compressor lacks variable capacity, running at full output even during partial-load conditions
- 75 dB noise level is noticeable during operation, especially compared to quieter variable-capacity units
- Price currently unavailable, making value comparison difficult against competing 2-ton systems
Who Should Buy
Best For
Homeowners in moderate climates who prioritize heating efficiency and want a straightforward, proven system without premium pricing. This works especially well for those replacing older furnaces where heating dominates energy usage.
Consider Alternatives If
Buyers in high-heat climates needing aggressive cooling or those prioritizing whisper-quiet operation should explore variable-capacity systems with 15+ SEER ratings instead.
Installation
Installation follows standard split-system procedures with straightforward refrigerant piping. The 3/8 inch liquid line and 3/4 inch suction line with matching valve sizes accommodate typical residential runs up to 50 feet. Upflow configuration suits basements or attic placement. PVC flue venting to the right side simplifies exhaust routing. The 115V single-phase, 60 Hz electrical requirement needs a 10.3 to 15 amp breaker, making integration into existing home wiring straightforward for most installations.
Warranty & Reliability
Coverage includes a lifetime heat exchanger warranty against defects, plus 10 years of parts replacement and 10 years of unit replacement if you register online. This tiered approach protects your largest investment (the heat exchanger) indefinitely while covering components and labor during the critical first decade. Registration is essential, so don't overlook that step after installation.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger, 10 Years Unit Replacement, and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 2 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | GMEC96 Installation Manual GMEC96 Specifications Sheet GMEC96 Owner's Manual GMEC96 Service Manual GMEC96 Replacement Parts Manual GMEC96 Brochure Goodman Furnace Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi-Speed - ECM |
| Maximum CFM | 1200 |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |