Review
The ACiQ ACIQ-24-EHPD-UPG is a mid range residential split system pairing a 2 ton air conditioner condenser with a matching gas furnace. This Goodman manufactured unit delivers 24,000 BTU cooling capacity and 60,000 BTU heating output in a compact upflow A coil configuration. It's positioned as a practical replacement for aging systems where owners want measurable efficiency improvements without stepping into premium tier pricing that adds $2,000 to $4,000 to project costs.
Efficiency is this system's strongest selling point. The condenser achieves 13 SEER1 rating using modern R454B refrigerant, while the furnace reaches 96% AFUE with two stage burner modulation. Real world heating costs drop 10 to 15 percent compared to 80-90% AFUE units. The variable speed ECM blower motor avoids wasting energy during partial load operation. Energy Star certification confirms these figures meet government standards. Cooling capacity of 24,000 BTU adequately handles a 2,000 to 2,400 square foot home depending on insulation and climate zone.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly compared to 80-90% units
- 13 SEER condenser with R454B refrigerant meets current EPA standards and Energy Star certification
- Variable speed ECM blower motor optimizes airflow and reduces electricity draw during partial load operation
- Two stage burners provide modulating heat output, improving comfort and reducing cycling
- Lifetime heat exchanger warranty covers the most expensive potential failure point
Cons
- Single stage compressor cannot modulate cooling capacity, limiting comfort precision on mild days
- 75 dB noise level is moderate, not ideal for bedrooms or quiet zones adjacent to condenser
- 10 year parts warranty requires online registration and is shorter than premium competitor offerings
Who Should Buy
Best For
Budget conscious homeowners replacing 10+ year old systems in climates with meaningful heating and cooling seasons. This system targets the sweet spot between entry level units and high efficiency variable capacity models.
Consider Alternatives If
Buyers prioritizing whisper quiet operation or those in mild climates where cooling dominates should evaluate quieter variable capacity units instead.
Installation
Installation complexity is moderate. The upflow A coil configuration fits most standard closet spaces or utility areas with 34.5 inch height and 17.5 inch width requirements. Copper line sets include 3/8 inch liquid and 3/4 inch suction connections with sweat valve fittings. PVC exhaust flue simplifies venting versus older metal ductwork. Most contractors complete residential installs within one day. Electrical needs are minimal at 115V single phase, 10.3 to 15 amp breaker.
Warranty & Reliability
Goodman covers the heat exchanger for the lifetime of the original owner, protecting against the most expensive component failure. Additional parts carry 10 year coverage with online registration required. This warranty positions well for homeowners keeping units 15 to 20 years, though it trails some competitors offering 10 to 20 year extended parts warranties without registration requirements.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | Lifetime Heat Exchanger and 10 Years Parts with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130242 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 15 amps |
| Min. Breaker Size | 10.3 amps |
| Tonnage | 2 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Install Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Style | A-Coil |
| AHRI Certificate Number | 7368833 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.