Review
The ACiQ 2-ton system represents Goodman's value-oriented entry into the mid-efficiency market segment. At $647, this upflow-configured package delivers both heating and cooling from a single SKU, simplifying inventory for contractors and purchasing decisions for homeowners. The A-coil design fits in tight attic spaces, and the compact 27.5-inch height makes it practical for retrofit applications where older furnaces sat in space-constrained locations.
Performance specs impress for the price bracket. The furnace achieves 96% AFUE efficiency with 80,000 BTU output and two-stage heating, while the air conditioner delivers 24,000 BTU (2 tons) at 14 SEER. The variable-speed ECM blower motor maxes out at 1,600 CFM and adjusts throughout the heating and cooling cycles, improving comfort and reducing standby energy consumption. R454B refrigerant handles the 3/8-inch liquid and 3/4-inch suction lines efficiently, meeting modern environmental standards without premium equipment costs.
Pros & Cons
Pros
- 96% AFUE rating on the furnace means lower heating bills and qualifies for some utility rebates
- 14 SEER cooling efficiency provides good performance for a 2-ton system at this price point
- Variable speed ECM blower motor optimizes airflow and reduces energy waste across seasons
- R454B refrigerant is modern, lower-GWP alternative to older refrigerants with fewer phase-out concerns
- 50-foot suction line with 3/4-inch insulation reduces installation headaches for non-adjacent equipment placement
- Two-stage burner heating gives better temperature control and reduced short-cycling
Cons
- Single-stage cooling condenser lacks modulation for part-load efficiency that dual-stage units offer
- Not Energy Star certified, so homeowners miss additional tax credits available with higher-tier equipment
- 71 dB noise level is on the higher side for residential units, may be noticeable in quiet neighborhoods
Who Should Buy
Best For
Contractors installing replacement systems in existing homes where upflow configuration is required and budget constraints matter. Homeowners in moderate climates seeking reliable heating and cooling without spending on premium two-stage or inverter-driven equipment.
Consider Alternatives If
Anyone needing Energy Star certification, homes requiring ultra-quiet operation, or regions with extreme heating demands where two-stage heating would provide noticeably better performance.
Installation
The 50-foot suction line with 3/4-inch insulation thickness is a genuine advantage, allowing furnace and condenser separation up to 50 feet with minimal efficiency loss. Electrical requirements are modest, 208/230V single phase at 14.3 to 25 amps, fitting standard residential panels without upgrades. Plastic PVC flue venting is standard, and right-side flue location works with most existing installations. Variable-speed motors require basic thermostat compatibility.
Warranty & Reliability
Ten-year parts coverage with online registration is competitive for this segment and reflects manufacturer confidence. Covers compressor, coil, and components against defects. Registration is required within 30 days of installation, so contractors must flag this at handoff. Labor is not included, typical for systems at this price.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Tonnage | 2 Ton |
| Style | A-Coil |
| Height | 27.5" |
| Width | 26" |
| Depth | 26" |
| Resources | Goodman Installation Manual Goodman Specifications Goodman Brochure Goodman Warranty Information Goodman Service Instructions Goodman Kit Instructions Goodman Parts Manual You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368835 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Flue Location | Right |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 14.3 amps |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions