Independent Review · Updated June 2026

2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow

High-efficiency gas furnace and AC combo for tight spaces and budget-conscious upgrades

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system delivers solid heating efficiency at 96% AFUE and respectable cooling at 14 SEER1 in a compact footprint ideal for retrofit applications where space is limited. It's best for homeowners upgrading older systems who want dependable performance without premium pricing, particularly in mild to moderate climates.

Review

The ACiQ 2-ton combination furnace and air conditioner arrives as a sensible middle-ground option in the crowded HVAC replacement market. Positioned at the entry level for efficiency seekers, this upflow unit targets contractors and homeowners upgrading from aging equipment without breaking budgets on premium brands. The compact 21-by-21-by-22-inch profile solves real installation headaches in basements and closets where standard 24-inch boxes won't fit.

Performance numbers tell a practical story: the furnace hits 96% AFUE with two-stage burners capable of modulating heat output, while the AC section delivers 80,000 BTU heating and 24,000 BTU cooling at 14 SEER1 efficiency. The variable-speed ECM blower reaches 1600 CFM maximum and adjusts speed to match actual demand, reducing energy waste during part-load operation. These specifications align well with 2-ton systems serving 1200-1600 square foot homes in moderate climates.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency minimizes heating fuel waste and reduces monthly winter bills by 10-15% versus 80% AFUE systems
  • Variable-speed ECM blower motor optimizes airflow at 1600 CFM maximum and reduces runtime energy consumption
  • Compact dimensions at 22 inches tall, 21 wide, and 21 deep fit tight equipment closets and basements where standard units won't
  • Dual-fuel capability handles both natural gas and propane, useful for properties without gas service
  • Two-stage burner modulates heating output for improved comfort and efficiency during partial-load conditions
  • PVC/plastic flue piping simplifies venting through existing plastic ductwork or condensing exhaust lines

Cons

  • 14 SEER1 cooling rating lags premium competitors at 16+ SEER2, meaning higher AC operating costs in hot climates
  • Single-stage compressor delivers fixed cooling output rather than variable capacity, reducing part-load efficiency
  • No Energy Star certification despite decent efficiency numbers, which disqualifies buyers seeking tax credits or rebates
  • 71 dB noise level at full capacity registers louder than variable-capacity alternatives, potentially noticeable in quiet settings

Who Should Buy

Best For

This system suits budget-conscious homeowners and light commercial properties replacing 15-25 year old equipment who prioritize heating efficiency over cooling performance. It's particularly valuable in northern regions, rental properties, and retrofit applications where furnace space is constrained.

Consider Alternatives If

Buyers in hot climates who run AC six months annually should look at higher SEER units, and anyone seeking Energy Star rebates or tax incentives will find this unit ineligible.

2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furn
$0
Buy at HVACDirect →

Installation

Installation requires 208/230 volt, 1-phase, 60 Hz power with breaker sizing between 14.3 and 25 amps. The unit accepts plastic PVC exhaust venting, eliminating expensive metal flue modifications. Liquid and suction lines use standard 3/8-inch and 3/4-inch copper with 50-foot maximum length and 3/4-inch insulation thickness, supporting typical retrofit jobs without major ductwork redesign.

Warranty & Reliability

ACiQ includes a 10-year comprehensive warranty activated through online registration, covering parts and compressor defects. Registration is required to unlock full coverage, and Goodman's evaporator coil carries matching 10-year protection. This warranty duration matches industry standards for mid-tier equipment but lacks the extended terms offered by premium manufacturers.

Specifications

SKUACIQ-24-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU24,000
Heating BTU80,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)71
Weight (in lbs)120.000000
FeatureSpec
AHRI Certificate Number7368835
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorVariable Speed - ECM
Maximum CFM1600
ConfigurationUpflow / Downflow
Flue LocationRight
Energy StarNo
Burner StagesTwo
Fuel TypePropane, Natural Gas
Height22"
Width21"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeRotary
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size25 amps
Min. Breaker Size14.3 amps
Tonnage3 Ton
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

Why is this system called 2-ton but rated for 3-ton tonnage in the specs? +
The title reflects the air conditioner capacity at 24,000 BTU cooling, which equals 2 tons. The 3-ton notation appears to reference a rating classification for combined system sizing. Always verify with the equipment manual for your specific installation requirements before ordering.
Can I install this upflow furnace in a horizontal position for attic placement? +
Yes, the configuration specs confirm upflow/horizontal capability, though horizontal attic installation requires dedicated return ductwork design. Consult the CAPF Installation Manual (available in resources) for proper downflow or horizontal conversion steps to ensure safe operation.
How does 96% AFUE compare to my old furnace's efficiency? +
Older furnaces from the 1990s-2000s typically operate at 78-80% AFUE, meaning 16-18% of fuel energy exits the flue as waste. This ACiQ unit captures 96% of fuel energy for heating, translating to roughly 15-20% lower heating bills depending on climate and usage patterns.
Is R454B refrigerant harder to service than older R410A systems? +
R454B is the EPA's preferred low-GWP refrigerant requiring certified technicians and proper recovery equipment like R410A. Availability continues improving, though some rural areas still have limited supply. Labor costs may run 5-10% higher than established R410A service protocols.
Does the 10-year warranty cover refrigerant leaks from installation mistakes? +
Warranty typically covers manufacturer defects and compressor failures, not installation errors or leak damage from improper charging. Review the full warranty document after registration to clarify coverage exclusions and claim procedures.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.