Independent Review · Updated June 2026

2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow

96% efficient gas furnace paired with 14 SEER cooling in one compact unit

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This 2-ton Goodman combo system is ideal for homeowners replacing aging furnace-AC setups in moderate climates or smaller homes. The 96% AFUE heating efficiency and 14 SEER cooling balance performance with reasonable operating costs, making it a solid mid-tier choice for budget-conscious upgrades.

Review

The Goodman 2-ton combo furnace and air conditioning system represents the practical middle ground in residential HVAC. With 80,000 BTU heating capacity and 24,000 BTU cooling, this upflow unit handles modest homes efficiently without premium pricing. It's a direct replacement for countless older dual systems still operating in the 80-90% efficiency range, making it an attractive upgrade path for cost-conscious homeowners.

Performance metrics show genuine efficiency gains. The furnace delivers 96% AFUE, meaning 96 cents of every heating dollar converts to usable heat, while the air conditioner reaches 14 SEER with R454B refrigerant. The two-stage burner modulates between high and low fire for comfort, and the multi-speed ECM blower runs at just 71 decibels. Maximum airflow reaches 1,200 CFM, adequate for homes up to 1,600 square feet in most climates.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency reduces winter heating bills significantly compared to 80-90% units
  • 14 SEER air conditioner meets ENERGY STAR standards with R454B low-GWP refrigerant
  • Two-stage burner and multi-speed ECM blower motor provide quieter operation at 71 dB
  • Lifetime heat exchanger warranty plus 10-year parts and unit coverage with registration
  • Compact A-coil design fits upflow or horizontal configurations in tight spaces

Cons

  • Single-stage cooling compressor cannot modulate capacity, leading to short cycling in mild weather
  • 115V electrical requirement limits installation flexibility in some older homes
  • Plastic PVC exhaust flue requirement adds installation costs for homes needing new ductwork

Who Should Buy

Best For

Homeowners in moderate climates replacing 15-20 year old furnace-AC combos who prioritize heating efficiency and want to stay under $3,000 total system cost. This works best for 1,200-1,500 square foot homes where 2-ton capacity matches actual heating and cooling loads.

Consider Alternatives If

Buyers in extreme climates needing 3+ ton capacity or those wanting variable-speed cooling should look at higher SEER2 models with multi-stage compressors.

2 Ton 14 SEER 96% AFUE 80,000 BTU Goodman Gas Furn
$0
Buy at HVACDirect →

Installation

Installation requires 115V single-phase power with a 14.3 to 25 amp breaker, making it compatible with standard residential service panels. The compact footprint measures 34.5 inches tall and 28.75 inches deep, fitting basement corners and closets. PVC exhaust venting simplifies installation compared to metal flues, though condensate drainage to floor drains or pumps is necessary given the 96% efficiency.

Warranty & Reliability

Goodman backs this unit with lifetime coverage on the heat exchanger, addressing the costliest component. Ten-year full replacement and parts warranties apply with online registration, protecting against major failures through the warranty period. This combination matches industry standards for mid-tier equipment.

Specifications

SKUACIQ-24-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU24,000
Heating BTU80,000
RefrigerantR454B
Electrical115 V. 1 Phase 60 Hz
WarrantyLifetime Heat Exchanger, 10 Years Unit Replacement, and 10 Years Parts with Online Registration
Decibel Level (dBA)71
Weight (in lbs)120.000000
FeatureSpec
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeRotary
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size25 amps
Min. Breaker Size14.3 amps
Tonnage3 Ton
Height34.5"
Width17.5"
Depth28.75"
ResourcesGMEC96 Installation Manual GMEC96 Specifications Sheet GMEC96 Owner's Manual GMEC96 Service Manual GMEC96 Replacement Parts Manual GMEC96 Brochure Goodman Furnace Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationUpflow/Horizontal
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorMulti-Speed - ECM
Maximum CFM1200
Flue LocationRight
Burner StagesTwo
Fuel TypeGas
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

Is this unit right for a 2,000 square foot home? +
The 2-ton, 24,000 BTU cooling capacity works best for homes under 1,600 square feet in moderate climates. Homes above 1,800 square feet typically need 2.5 to 3 tons. Calculate your actual cooling load before purchasing to avoid undersizing.
Can this furnace use my existing ductwork and venting? +
The upflow A-coil accepts existing return and supply ducts easily. However, the plastic PVC exhaust flue requirement means you may need new venting if your current system uses metal or masonry chimneys. Consult a local HVAC installer for existing venting compatibility.
How does 14 SEER compare to newer 15-18 SEER systems? +
14 SEER cooling costs roughly 10-15% more annually than 16 SEER units with variable-speed compressors. This trade-off saves 20-30% upfront. For homeowners staying 10-12 years, the lower purchase price often outweighs efficiency losses.
Does this work with smart thermostats or zone control? +
Yes, the multi-speed ECM blower integrates with standard smart thermostats. The two-stage burner responds to temperature setbacks well. However, true zone control requires dampers and multi-stage equipment, which this single-stage cooling unit doesn't fully support.
What does the lifetime heat exchanger warranty actually cover? +
It covers defects in the heat exchanger material and construction forever, with no time limit. However, labor costs for removal and replacement fall outside this coverage, typically costing $500-1,200 after year ten.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.