The Goodman 2-ton 96% AFUE furnace with 14 SEER AC coil strikes a practical balance between performance and cost. This Energy Star qualified system combines gas heating and air conditioning in a compact 21x21x22 inch package rated for upflow or horizontal installation. Goodman's reputation for no-nonsense reliability and parts availability makes this a solid choice for budget-conscious homeowners and contractors who prioritize straightforward equipment over cutting-edge features.
Performance specs reveal capable year-round comfort. The furnace delivers 24,000 BTU heating with single-stage burner operation, while the AC side matches with 24,000 BTU cooling capacity at 14 SEER efficiency. The multi-speed blower motor adjusts between low and high speeds depending on demand, maximizing efficiency during mild weather. Operating at 208/230 volts single-phase with a 25-amp maximum breaker, electrical integration remains straightforward. The scroll compressor and R410A refrigerant provide reliable cooling without ozone depletion concerns.
Pros & Cons
Pros
- 96% AFUE furnace efficiency means only 4% fuel waste, translating to lower heating bills for gas-heated homes
- 14 SEER cooling rating with R410A refrigerant meets modern environmental standards and runs quieter at 75 dB
- Multi-speed blower motor allows precise airflow control, reducing energy consumption during partial-load conditions
- 10-year warranty with online registration covers parts and labor for peace of mind
- PVC exhaust compatible, simplifying installation in retrofit applications where metal flues are problematic
- Energy Star rated, qualifying homeowners for potential utility rebates and tax credits
Cons
- Single-stage burner and condenser limit operational flexibility compared to variable-capacity systems
- 24,000 BTU capacity may be undersized for larger homes or extreme cold climates requiring auxiliary heating
- Single-stage design cycles on and off rather than modulating, slightly less efficient than multi-stage alternatives
- Weight of 22 lbs and compact 21x21x22 inch dimensions require careful ductwork planning for attic or crawlspace installation
Who Should Buy
Best For
Homeowners in zones 4-6 replacing aging 80% AFUE furnaces, or those building new 1,500-2,500 square foot homes seeking Energy Star rebates. Contractors installing retrofit systems in tight spaces will appreciate the compact footprint and straightforward single-stage design.
Consider Alternatives If
Anyone in extremely cold climates (zone 7+) needing heating capacity above 24,000 BTU, or homeowners prioritizing ultra-high efficiency should explore 98% AFUE furnaces and 16+ SEER heat pumps instead.
Installation
Installation requires PVC or plastic exhaust flue venting, simplifying retrofit projects where metal chimneys are unavailable. The right-side flue location offers flexible ductwork routing. Suction and liquid lines measure 3/4 inch and 3/8 inch respectively, with 50-foot maximum line length capacity. Multi-speed blower operation requires proper ductwork static pressure design for optimal performance. Technicians should reference the CAPF Installation Manual and Specifications Sheet for detailed airflow and electrical requirements.
Warranty & Reliability
Goodman provides 10 years coverage on parts and compressor when registered online, a competitive industry standard. Registration is straightforward and highly recommended to activate the full term. The Evaporator Coil carries separate warranty documentation. Coverage protects against manufacturing defects but excludes maintenance, misuse, or improper installation. Online registration typically completes within minutes through Goodman's portal.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 24,000 |
| Heating BTU | 24,000 |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi Speed |
| Maximum CFM | 1600 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Height | 22" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 15.1 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions