Review
The ACiQ ACIQ-24-EHPD-UPG is a no-frills 2-ton heat pump system positioned as a pragmatic upgrade for homeowners tired of aging furnaces. Built on Goodman's proven platform, this unit combines gas furnace heating with heat pump cooling in one compact upflow cabinet. At $643, it undercuts premium brands significantly while maintaining respectable efficiency ratings. The 120-pound footprint fits standard closets or basements, and the A-coil design integrates cleanly with existing ductwork.
Performance specs tell a solid story for the price point. The gas furnace delivers 96% AFUE efficiency with 24,000 BTU output, meaning minimal energy waste during winter heating cycles. The heat pump side produces matching 24,000 BTU cooling capacity at 14 SEER, qualifying for Energy Star certification. A multi-speed blower adjusts CFM up to 1200 for balanced comfort across varying loads. Single-stage operation means it runs at full capacity rather than modulating, which is typical at this price level but less efficient during mild weather.
Pros & Cons
Pros
- 96% AFUE furnace efficiency delivers real savings on gas bills compared to older 80-85% systems
- 14 SEER rating meets Energy Star standards and qualifies for utility rebates in many regions
- 2-ton capacity handles typical single-story or smaller homes effectively with 24,000 BTU output
- Multi-speed blower motor optimizes comfort and reduces runtime noise compared to single-speed designs
- R454B refrigerant is newer, lower-GWP alternative to R410A with growing technician familiarity
Cons
- Single-stage compressor and condenser mean less efficient modulation during mild weather cycling
- 70 dB noise level is louder than premium variable-speed units, notable for sound-sensitive locations
- Requires 208/230V electrical service, limiting installation flexibility in some older homes
Who Should Buy
Best For
Budget-conscious homeowners replacing 15+ year old systems who need a reliable, efficient combo unit without premium pricing. Contractors serving price-sensitive markets will appreciate the rebate eligibility and straightforward Goodman-brand support.
Consider Alternatives If
Anyone prioritizing whisper-quiet operation or maximum modulation efficiency should explore variable-stage competitors, which cost more but deliver better part-load performance.
Installation
Installation requires 208/230V single-phase 60Hz electrical service with breaker sizing between 17.1 and 25 amps. The unit accepts 3/8-inch liquid lines and 3/4-inch suction lines with sweat valve connections. Plastic PVC exhaust flue is required for the gas side. Standard upflow/horizontal positioning accommodates most residential installations. Technicians familiar with Goodman equipment will appreciate straightforward connections and well-documented installation guides.
Warranty & Reliability
The 10-year warranty requires online registration to activate full coverage. This is competitive for the price segment and covers defects in materials and workmanship. Registration is simple and typically completed at point of sale. Extended coverage options may be available through contractors. Keep documentation and proof of professional installation to ensure claim eligibility.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 24,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 70 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Tonnage | 2 Ton |
| Style | A-Coil |
| Height | 38.25" |
| Width | 29" |
| Depth | 29" |
| Resources | Goodman Specifications Goodman Customer Brochure Goodman Installation Instructions Goodman Kit Instructions Goodman Parts Manual Goodman Service Manual Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi Speed |
| Maximum CFM | 1200 |
| Flue Location | Right |
| Burner Stages | Single |
| Fuel Type | Gas |
| Replaces | GSZ140251 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 17.1 amps |
| Valve Type | Sweat |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.