Review
The ACiQ 2-ton vertical A-coil air conditioner positions itself as a practical middle-ground solution for residential cooling upgrades. At 24,000 BTU capacity with 14 SEER efficiency, it competes against mid-tier units from major manufacturers while maintaining aggressive pricing. The vertical cased coil design (14 inches wide, 21 inches deep) fits standard ductwork configurations, and R454B refrigerant ensures forward compatibility with evolving EPA standards. This unit targets contractors managing volume replacements and budget-conscious homeowners unwilling to stretch for premium variable-capacity systems.
Performance-wise, the 24,000 BTU output adequately handles 2-ton cooling loads in moderate climates. The 14 SEER rating translates to measurable savings compared to 10-12 SEER legacy equipment, though it trails high-efficiency competitors at 16-18 SEER. A rotary compressor drives the single-stage operation, offering straightforward reliability without variable-capacity modulation. The 71 dB noise level ranks at the louder end of acceptable, and electrical requirements (208/230V, 1-phase, 14.3-25A breaker) remain standard for most residential installations, requiring no special panel upgrades.
Pros & Cons
Pros
- 14 SEER rating delivers respectable efficiency gains over older 10-13 SEER units, reducing cooling costs by approximately 10-15% annually
- R454B refrigerant is EPA-compliant and future-proof, avoiding obsolescence as regulations tighten
- Rotary compressor is proven technology, generally more reliable than reciprocating designs in this tonnage class
- Compact footprint at 14 inches wide and 22 inches tall simplifies installation in tight attic or closet spaces
- 10-year warranty with online registration provides solid long-term protection for residential applications
Cons
- Single-stage compressor lacks variable capacity, meaning it runs at full output or off with no modulation for part-load efficiency
- 71 dB noise level is noticeably louder than variable-stage competitors, potentially problematic in noise-sensitive locations
- Not Energy Star certified, missing qualification for some rebate programs and utility incentives
- Specs list conflicting tonnage (2-ton vs 3-ton designation), creating confusion during specification and ordering
Who Should Buy
Best For
Contractors managing replacement projects in residential homes where budget constraints matter and climate zones rarely demand maximum cooling efficiency. Homeowners in moderate climates seeking straightforward, dependable equipment without premium pricing for variable-speed features.
Consider Alternatives If
Anyone in hot climates seeking maximum seasonal efficiency or homeowners prioritizing quiet operation, since this unit's 71 dB output and single-stage design don't optimize for extended cooling seasons.
Installation
Installation involves standard refrigerant line connections using 3/8-inch liquid lines and 3/4-inch suction lines, both available in 50-foot lengths with 3/4-inch insulation thickness. The compact dimensions (22 inches tall, 14 inches wide) fit tight attic spaces. Mounting requires standard equipment pad installation. Electrical work demands straightforward single-phase 208/230V connection with appropriate breaker sizing between 14.3 and 25 amps. No special tools or refrigerant recovery equipment beyond industry standards is necessary.
Warranty & Reliability
ACiQ provides 10 years of parts and compressor coverage when registered online, a solid offering for residential use. Registration is straightforward and typically completed during installation. This warranty covers manufacturing defects but excludes damage from improper installation, refrigerant leaks from external sources, or lack of maintenance. Online registration is mandatory to activate coverage, so contractors should ensure homeowners complete this step immediately.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | No |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 14.3 amps |
| Tonnage | 3 Ton |
| Height | 22" |
| Width | 14" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow / Downflow |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |