Review
The Goodman 2-ton horizontal gas furnace and air conditioner system lands squarely in the practical mid-market segment. At $2024, it positions itself as the value player against premium brands like Carrier AquaEdge and Lennox XC series. The unit combines a natural gas or propane furnace with an R410A compatible air conditioner in a compact horizontal configuration suitable for attic or crawlspace installation. Energy Star certification signals this system meets EPA efficiency thresholds that matter to utility-conscious homeowners.
Performance metrics reveal a competent, not exceptional, package. The furnace delivers 60,000 BTU heating capacity at 80% AFUE efficiency, meaning 80 cents of every energy dollar converts to usable heat. The air conditioner produces 23,600 cooling BTU with a 16 SEER rating, matching mid-tier competitors. A variable-speed blower and two-stage burner provide operational flexibility. The scroll compressor generates 71.5 dB noise, comparable to residential window units. These specs indicate steady, reliable performance rather than premium efficiency gains.
Pros & Cons
Pros
- 16 SEER rating exceeds the 14 SEER minimum, delivering measurable cooling cost savings over standard units
- 80% AFUE furnace efficiency qualifies for Energy Star certification, reducing heating costs 15-20% versus 78% AFUE models
- Variable-speed blower motor with 1600 CFM maximum allows precise airflow control and better humidity management
- Two-stage burner provides modulated heating, reducing energy waste during mild weather
- Scroll compressor technology is durable and quieter than older designs, operating at 71.5 dB
Cons
- Title claims 2 tons but specs list 3 tons and 23,600 cooling BTU, creating sizing confusion that could lead to installation mistakes
- 60,000 BTU heating capacity is modest and may require supplemental heat in very cold climates without proper load calculation
- Single-stage compressor limits efficiency gains compared to two-stage or variable-capacity competitors like Lennox or Carrier
Who Should Buy
Best For
Homeowners in mild-to-moderate climates upgrading 5-10 year old systems who prioritize energy savings and reliability over cutting-edge features. Contractors seeking a solid mid-range option for 1200-1600 square foot homes without premium budget constraints.
Consider Alternatives If
Anyone in severe climate zones needing robust heating capacity, or buyers expecting the absolute quietest operation, should compare two-stage compressor alternatives.
Installation
The horizontal A-coil configuration simplifies attic mounting and requires standard refrigerant line connections using 3/8-inch liquid and 3/4-inch suction lines with 3/4-inch insulation thickness. Metal exhaust flue is mandatory for proper venting. Electrical requirements are modest, 120V single-phase with 12.4 to 20-amp breaker sizing. Most certified HVAC technicians complete installation in 4-6 hours on retrofit jobs, though new construction may require additional ductwork adaptation.
Warranty & Reliability
Goodman offers a full 10-year warranty covering parts and labor when registered online within 30 days of installation. This matches industry standard for mid-tier systems and covers compressor failure, coil leaks, and component defects. Registration is straightforward but required, so document your purchase immediately. The warranty does not cover improper installation, refrigerant, or damage from external causes.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 60,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 3 Ton |
| Height | 21.125" |
| Width | 17.5" |
| Depth | 26" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 204633301 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 1600 |
| Configuration | Horizontal |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.