Review
The Goodman 2-ton split system represents a practical middle-ground option in today's HVAC market. This upflow configuration pairs an 80% AFUE gas furnace rated at 100,000 BTU with a 3.5-ton air conditioning condenser capable of 23,600 cooling BTU. Energy Star certification and a scroll compressor suggest solid engineering for residential applications. At this price point, it competes directly with mid-tier contractor packages from Lennox and Carrier, making it worth careful evaluation.
Performance specs tell an honest story about efficiency positioning. The 15 SEER cooling efficiency exceeds baseline requirements but trails high-efficiency models at 18+ SEER. The 80% AFUE furnace operates at industry minimum efficiency, meaning 20% of heating energy vents as waste. Two-stage burner operation and a variable-speed blower at 2000 CFM maximum do mitigate these limitations by reducing runtime and improving part-load response. Real-world heating and cooling costs will fall below 1990s equipment but not dramatically below 2010s systems.
Pros & Cons
Pros
- Variable-speed blower motor reduces short-cycling and improves temperature consistency throughout the home
- Two-stage burner on furnace allows low-fire operation for better part-load efficiency in mild weather
- Energy Star certified with 16 SEER1 condenser rating, exceeding the minimum 14 SEER baseline
- Scroll compressor design runs quieter at 71.5 dBA and offers proven reliability in residential applications
- 10-year warranty with online registration provides meaningful protection for this $0 system investment
Cons
- 80% AFUE furnace is baseline efficiency, not high-efficiency, leaving potential energy savings on the table compared to 95% models
- Single-stage condenser cannot modulate cooling capacity, limiting part-load efficiency during shoulder seasons
- Requires metal exhaust flue, which may necessitate additional venting modifications in some homes
Who Should Buy
Best For
Homeowners in moderate climates seeking a dependable system replacement without upgrading to premium efficiency tiers. This setup appeals to budget-conscious buyers who value the variable-speed blower's comfort improvements over high-end modulation features.
Consider Alternatives If
Anyone in extreme climates or with high heating/cooling costs should consider 95% AFUE furnaces and 18+ SEER condenser units instead.
Installation
Installation complexity ranks moderate. The unit requires 120V single-phase 60Hz power with 12.4 to 20 amp breaker sizing, standard for most residential panels. Suction lines come pre-insulated at 3/4 inch thickness with 50 feet maximum length, simplifying fieldwork. Metal exhaust flue requirement means furnace placement cannot use standard PVC venting. Technicians should allow 6 to 8 hours for a complete replacement including electrical, refrigerant, and gas connections.
Warranty & Reliability
Goodman backs this system with a 10-year parts warranty, activated through online registration. Coverage applies to the compressor, condenser coil, and furnace heat exchanger. This timeframe is standard across mid-tier manufacturers but trails extended warranties available from higher-priced brands. Registration is simple but mandatory to activate full protection, so document your purchase immediately upon installation.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 100,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 3.5 Ton |
| Height | 26" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions