Review
Goodman's 2-ton gas furnace and air conditioner system occupies the practical middle ground in the residential HVAC market. At $1,909, this upflow-configured unit targets homeowners who need reliable performance without luxury pricing. The system combines a 60,000 BTU furnace rated at 80% AFUE with a 23,600 BTU cooling condenser delivering 16 SEER2 efficiency. Online Supply's position as the distributor means direct pricing without middleman markup, making this an attractive option for both DIY installers and contractors seeking volume equipment.
Performance specs reveal a competent system with solid engineering choices. The furnace's two-stage burner modulates between high and low fire, which reduces short-cycling and improves comfort during shoulder seasons. The air conditioner uses a scroll compressor with R410A or R22 refrigerant compatibility, paired with a variable-speed blower capable of 1,600 CFM maximum airflow. At 71.5 dB, cooling operation produces noticeable sound typical for single-stage units. The 80% AFUE rating means 20 cents of every heating dollar escapes through the flue, a trade-off balanced by the lower purchase price compared to 95% high-efficiency models.
Pros & Cons
Pros
- 16 SEER2 condenser exceeds the stated 15 SEER rating, providing genuine cooling efficiency
- Two-stage burner on furnace adapts to heating demand, reducing energy waste during mild weather
- Variable-speed blower motor allows precise airflow management and quieter operation
- Energy Star certified and AHRI certified (204633301) for verified performance claims
- $1,909 price point undercuts comparable two-ton systems by $300 to $500
Cons
- 80% AFUE is acceptable but not competitive with 95% high-efficiency condensing furnaces that save more on heating bills
- Single-stage compressor offers no part-load efficiency like variable-capacity models do
- 71.5 dB noise level is audible during operation, noticeably louder than quieter units
Who Should Buy
Best For
Homeowners in moderate climates (zones 4-6) replacing 10+ year old systems who prioritize upfront cost over maximum efficiency. Contractors seeking reliable equipment for volume residential replacements will appreciate the proven Goodman platform and straightforward installation.
Consider Alternatives If
Anyone in cold climates (zones 1-3) should explore 95% AFUE furnaces that recover heat from exhaust, and buyers in hot climates wanting whisper-quiet operation should examine variable-capacity compressor units.
Installation
This upflow system requires metal exhaust flue and standard 120V single-phase 60 Hz electrical service with 12.4 to 20 amp breaker sizing. The A-coil design fits standard furnace closets with 26-inch height. Refrigerant lines need proper 3/4-inch suction line insulation (included at 50 feet) and 3/8-inch liquid line sizing. Installation is straightforward for certified technicians familiar with Goodman platforms, though coil matching and proper ductwork are essential for rated performance.
Warranty & Reliability
Goodman backs this system with 10 years of parts coverage when you register online after purchase. This warranty typically covers compressor, coil, and heat exchanger failures. Registration is required to activate coverage, so keep your documentation. Ten years is competitive for mid-range equipment, though some premium brands offer comparable terms without registration requirements.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 60,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 3 Ton |
| Height | 26" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 204633301 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 1600 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.