The Goodman 2-ton system represents a practical middle ground in the residential HVAC market. This upflow configuration combines an 80% AFUE furnace rated at 80,000 BTU with a 16 SEER air conditioner cooling 23,600 BTU. At $2,168, it delivers solid performance for replacement applications in moderate climates without stretching budgets toward premium equipment. The unit carries AHRI certification number 204633302, confirming manufacturer specifications and contractor confidence in the pairing.
Performance metrics show this system balances heating and cooling competently. The furnace operates with two-stage burners and variable-speed blower capable of 2,000 CFM maximum airflow, allowing better temperature control than single-stage alternatives. The air conditioner uses a scroll compressor with 3/8 inch liquid and 3/4 inch suction lines, running at 71.5 decibels, which is moderate noise for a 2-ton cooler. The variable-speed motor reduces energy consumption during partial-load conditions, a real benefit during spring and fall when demand fluctuates.
Pros & Cons
Pros
- 16 SEER air conditioner provides above-average cooling efficiency for the price range
- Variable-speed blower motor improves comfort and reduces energy waste compared to single-stage designs
- 80,000 BTU heating capacity with two-stage burners offers better modulation than single-stage furnaces
- Compact 21 by 21 by 22 inch footprint fits tight mechanical closets and basement spaces
- 10-year warranty with online registration covers parts and labor concerns
- Energy Star certified, qualifying for some utility rebates and tax credits
Cons
- 80% AFUE is standard efficiency, not high-efficiency, so heating costs run higher than 95% AFUE units
- Single-stage condenser compressor may cycle more frequently than variable-capacity systems in mild weather
- R410A or R22 refrigerant options mean compatibility questions exist with existing systems
Who Should Buy
Best For
Homeowners in moderate climates replacing a failed furnace and air conditioner who want good efficiency without premium pricing. This system works well for homes under 2,500 square feet where a 2-ton capacity meets actual load calculations and budget constraints are realistic.
Consider Alternatives If
Anyone in cold climates needing maximum heating efficiency should look at 95% AFUE furnaces, and homeowners seeking cutting-edge cooling performance should consider variable-capacity compressors with SEER ratings above 18.
Installation
Installation requires metal exhaust flue piping and standard 120V single-phase 60 Hz electrical service. Breaker sizing demands 12.4 to 20 amps maximum. The compact 22-pound weight and 21 by 21 by 22 inch dimensions simplify handling in tight spaces. Line sets can extend 50 feet with 3/4 inch suction line insulation already included, reducing labor time on jobs with distance between indoor and outdoor units.
Warranty & Reliability
The 10-year parts and labor warranty activates upon online registration, a straightforward process most contractors complete at installation. This coverage protects against compressor failure, heat exchanger defects, and component breakdowns during the first decade. Registration is essential, as unregistered units receive limited coverage, so confirm completion before the customer takes possession.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 80,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 2.5 Ton |
| Height | 22" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 204633302 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |