Goodman's GSX16S241 replacement unit pairs a high-efficiency gas furnace with a solid-performing air conditioner in a space-conscious upflow configuration. This combo system targets the midmarket segment where contractors need reliable equipment meeting modern energy codes without premium pricing. The Energy Star certification and strong AFUE rating reflect current efficiency standards, positioning it as a practical choice for homeowners in moderate climates seeking better utility bill performance.
The furnace delivers 30,000 BTU heating output at 96% AFUE efficiency, translating to minimal fuel waste during operation. The air conditioner side generates 23,600 BTU cooling with a 16 SEER2 rating, providing solid seasonal performance for cooling-dominant periods. The two-stage burner and multi-speed ECM blower motor allow responsive output modulation, improving comfort while reducing short cycling. Single-stage compressor operation means it runs full capacity until thermostat demand drops, a practical trade-off versus variable-capacity systems.
Pros & Cons
Pros
- 96% AFUE furnace efficiency minimizes heating costs in moderate climates
- 16 SEER2 air conditioner rating (Energy Star certified) provides excellent cooling efficiency
- Multi-speed ECM blower motor with 1,200 CFM maximum adapts to varying load conditions
- Two-stage burner allows modulating heat output for improved comfort and efficiency
- PVC flue compatibility simplifies venting in newer construction or retrofit applications
- 10-year warranty with online registration provides solid coverage protection
Cons
- Specification mismatch: title claims 2 tons cooling but unit specs show 3 tons, creating confusion
- Single-stage compressor cannot modulate cooling capacity for variable demand
- 23,600 BTU cooling output actually represents high capacity for stated tonnage rating
- No pricing listed makes budget planning impossible for contractors and homeowners
Who Should Buy
Best For
Homeowners upgrading from older Goodman GSX16S241 systems who want direct replacement compatibility with minimal ductwork changes. Contractors installing standard upflow systems in homes where space constraints require compact footprints, particularly in attic or closet installations.
Consider Alternatives If
Anyone needing variable-capacity cooling should look at two-stage compressor models instead, as this unit's single-stage design cycles on and off rather than modulating output.
Installation
Upflow or downflow mounting flexibility accommodates various installation scenarios, from attic to basement placements. The right-side flue location with PVC venting simplifies new construction or retrofit work. Standard 3/8-inch liquid and 3/4-inch suction line connections interface with existing copper runs. Electrical requirements are minimal: 115V single-phase 60Hz with 12.4 to 20-amp breaker sizing fits standard residential panels without dedicated upgrades.
Warranty & Reliability
The 10-year parts and labor warranty activates upon online registration, providing solid coverage for manufacturing defects and component failures. This warranty duration is competitive for mid-tier equipment and covers both furnace and condenser. Registration is required, so new owners must complete paperwork promptly to activate coverage protection.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 30,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 3 Ton |
| Height | 26" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Multi-Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Gas |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |