Review
The Goodman 2-ton gas furnace and air conditioner system sits squarely in the practical middle ground between budget equipment and high-end efficiency units. At $643, this downflow configuration targets homeowners upgrading systems installed before 2005 who want meaningful performance gains without six-figure investment. The combination of a 97% AFUE furnace and 14 SEER condenser reflects Goodman's reputation for delivering reliable equipment at contractor-friendly pricing.
The furnace generates 80,000 BTU with modulating burner stages that continuously adjust to heating demand rather than cycling on and off. The air conditioner delivers 24,000 BTU cooling with a rotary compressor rated at single-stage operation. The variable-speed ECM blower motor maxes out at 1,200 CFM and operates at 71 dB, quiet enough for bedrooms and living areas. These specs translate to measurable winter savings: a 97% AFUE unit loses only 3% of fuel energy up the flue, compared to 8-10% for equipment from the 1990s.
Pros & Cons
Pros
- 97% AFUE heating efficiency reduces winter fuel costs by 15-25% versus older single-stage furnaces
- Modulating gas burner adjusts output in real time, improving comfort and cutting energy waste
- 14 SEER condenser with R454B refrigerant meets current efficiency standards
- Variable-speed ECM blower motor runs quietly at 71 dB and matches heating/cooling to actual demand
- 10-year warranty with online registration covers both major components
Cons
- Single-stage compressor cannot adjust cooling capacity, resulting in less precise temperature control than two-stage units
- 14 SEER is solid but trails 16-18 SEER models available at 20-30% higher cost
- PVC exhaust flue requirement limits installation flexibility in some older homes
Who Should Buy
Best For
Homeowners in mixed climates where heating costs represent 50% or more of annual HVAC expenses will see the fastest payback. Contractors installing replacement systems in suburban neighborhoods appreciate the straightforward downflow configuration and solid AHRI certification.
Consider Alternatives If
High-efficiency seekers willing to invest $1,200-1,500 for SEER 16+ units should explore premium models. Properties with metal exhaust venting already installed may face conversion costs.
Installation
This downflow A-coil configuration installs in utility closets, attics, and basements with limited horizontal space. Valve sizes (3/8 inch liquid, 3/4 inch suction) match standard refrigerant line diameters. The PVC exhaust flue requirement simplifies installation in many homes but may require venting modifications in older properties with metal chimneys. Total unit dimensions are 34.5 inches high, 17.5 inches wide, and 28.75 inches deep.
Warranty & Reliability
Goodman's 10-year parts warranty applies when you register the unit online within 30 days of installation. This covers compressor, heat exchanger, and control boards but typically excludes wear items like capacitors and contactors. Registration is straightforward and takes five minutes on Goodman's website, making this a meaningful extended protection compared to standard 5-year coverage.
Specifications
| SKU | ACIQ-24-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 24,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 25 amps |
| Min. Breaker Size | 14.3 amps |
| Tonnage | 3 Ton |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Downflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| AHRI Certificate Number | 7424270 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Flue Location | Right |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |