Independent Review · Updated June 2026

2 Ton 15 SEER 97% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Horizontal

97% AFUE furnace with 16 SEER2 cooling delivers premium efficiency in compact horizontal form

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 15 SEER 97% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Horizontal
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This system excels for homeowners upgrading older equipment who want measurable energy savings without replacing ductwork. The 97% AFUE furnace and 16 SEER2 condenser make it ideal for attics or crawlspaces where horizontal configuration fits naturally.

Review

This Goodman horizontal system represents a solid midrange option for HVAC replacement in homes where space constraints matter. The combination of an 80,000 BTU furnace with 97% AFUE and a 23,600 BTU cooling capacity condenser targets contractors managing attic and crawlspace installations. SKU LS38343850 carries a 10-year warranty and qualifies for ENERGY STAR, signaling genuine efficiency credentials rather than marketing claims.

Real-world performance hinges on the furnace's modulating burner and the condenser's variable-speed ECM blower. The 97% AFUE rating means nearly all fuel converts to heat, with only 3% wasted up the PVC flue. At 16 SEER2 cooling and 71.5 dB operating noise, the air conditioning side delivers respectable quiet operation. However, the single-stage compressor design means cooling capacity stays fixed rather than ramping down in mild weather, a tradeoff against the efficiency gains.

Pros & Cons

Pros

  • 97% AFUE furnace efficiency reduces heating costs significantly compared to 80s-era units
  • 16 SEER2 cooling rating qualifies for ENERGY STAR and utility rebates, lowering total installed cost
  • Modulating gas burner and variable-speed ECM blower motor reduce short-cycling and improve comfort
  • Compact horizontal dimensions (21.125 inches H x 17.5 inches W x 26 inches D) fit tight attic spaces
  • PVC exhaust compatibility simplifies venting in modern homes without masonry chimneys

Cons

  • Single-stage condenser design may cycle more frequently in extreme heat, reducing part-load efficiency gains
  • 3-ton condenser paired with furnace creates oversizing concerns if original AC was 2 tons, potentially wasting cooling capacity
  • Limited documentation on matched system performance, AHRI certificate references unit pairing but individual component ratings less clear

Who Should Buy

Best For

Homeowners in moderate climates replacing 20+ year old systems who want straightforward efficiency gains without major renovation. Contractors installing in existing horizontal/downflow configurations where ducting allows for proper airflow without major modifications.

Consider Alternatives If

Anyone needing a true 2-ton system should verify tonnage carefully, as this unit ships as 3-ton capacity despite product title saying 2-ton. Those requiring ultra-high efficiency should compare two-stage or variable-capacity equipment.

2 Ton 15 SEER 97% AFUE 80,000 BTU Goodman Gas Furn
$0
Buy at HVACDirect →

Installation

Horizontal orientation requires proper drain placement and slightly different ductwork connection geometry than vertical units. The 1200 CFM maximum airflow and 3/8-inch liquid line connections are straightforward for experienced installers. PVC exhaust needs termination at least 3 feet from windows and doors per code. Pre-charge refrigerant configuration (R410A or R22 compatibility) allows flexibility for existing lineset retrofit jobs without complete system evacuation in many cases.

Warranty & Reliability

The 10-year parts warranty requires online registration, a common Goodman requirement that many homeowners overlook. Coverage includes compressor, which typically fails between years 5 and 8 in poorly maintained systems. This protection adds genuine value versus no-name brands offering 5-year limited coverage. Evaporator coil carries separate warranty documentation, important if future refrigerant leaks develop.

Specifications

SKULS38343850
Brand/ManufacturerOnline Supply
Cooling BTU23,600
Heating BTU80,000
RefrigerantR410A or R22
Electrical115 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)71.5
Weight (in lbs)22.000000
FeatureSpec
ReplacesGSX16S241
Energy StarYes
SEER1 (Efficiency)16
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size20 amps
Min. Breaker Size12.4 amps
Tonnage3 Ton
Height21.125"
Width17.5"
Depth26"
ResourcesCHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
AHRI Certificate Number7424270
Airflow DirectionDownflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Product FeaturesRebate Available
Furnace Efficiency / AFUE97%
Blower MotorVariable Speed - ECM
Maximum CFM1200
ConfigurationHorizontal
Flue LocationRight
Burner StagesModulating
Fuel TypePropane, Natural Gas
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil
Suction Line Insulation Thickness3/4"
Length50 feet

Frequently Asked Questions

Why does the product title say 2-ton but specs show 3-ton capacity? +
The furnace matches original 2-ton systems, but the condenser unit itself is 3-ton rated. This creates oversizing in the cooling circuit. Verify with Online Supply whether this pairing is intentional for your climate zone or if a true 2-ton condenser is available.
Can this replace my old R22 equipment without replacing lineset? +
Yes, this unit accepts both R410A and R22 refrigerant. If existing lineset is properly sized with 3/8-inch liquid and 3/4-inch suction lines, you can avoid lineset replacement. However, R22 systems over 10 years old often have contaminated lines, requiring flushing before conversion.
How much will my heating bills drop with 97% AFUE versus my current 78% unit? +
A 19-point AFUE improvement typically cuts heating costs 15-20% annually depending on climate. In cold climates averaging $1,200 yearly heating costs, expect $180-240 annual savings. Payback ranges 7-10 years without utility rebates, often 4-6 years with available incentives.
Is 16 SEER2 the same as old SEER ratings I see online? +
No, SEER2 uses updated testing standards and typically runs 15-20% lower than legacy SEER ratings. A 16 SEER2 unit roughly equals an old 19-21 SEER rating. The spec sheet confirms SEER1 as 16, so verify which standard your utility rebate program requires before applying.
What electrical work do I need before installation? +
The unit requires 115V single-phase power with a 12.4-20 amp breaker. Most homes have adequate service already. Run a new dedicated circuit if the furnace location moved from original placement, standard practice costing $150-300 in labor.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.