Review
This Goodman combination system pairs a 60,000 BTU gas furnace with a 2-ton air conditioning condenser rated at 23,600 cooling BTU. Goodman continues to hold contractor mindshare with straightforward engineering and accessible pricing. The upflow A-coil configuration fits most residential installations, and the system qualifies as Energy Star certified, signaling compliance with current efficiency standards. Online Supply positions this unit as a reliable replacement for legacy equipment in markets where quick deployment matters.
The furnace delivers 97% AFUE using a modulating burner that adjusts flame intensity rather than cycling on and off, reducing runtime and temperature swings. The condenser achieves 16 SEER2 efficiency with a scroll compressor operating on R410A or R22 refrigerant. The variable-speed ECM blower motor caps out at 1,200 CFM and responds to thermostat calls instead of running flat-out, lowering electricity draw. These efficiency features work together to reduce monthly utility bills for households running both heating and cooling across the year.
Pros & Cons
Pros
- 97% AFUE furnace efficiency with modulating burner stages reduces gas consumption compared to single-stage units
- 16 SEER2 cooling efficiency and Energy Star certification qualify for most utility rebates
- Variable-speed ECM blower motor adjusts to actual heating/cooling demand, lowering runtime costs
- Scroll compressor design is proven reliable and quieter than reciprocating alternatives at 71.5 dB
- PVC exhaust flue compatibility simplifies venting in modern homes without masonry chimneys
- 10-year warranty with online registration provides reasonable coverage for parts and labor
Cons
- Spec sheet lists both 2 Ton and 3 Ton tonnage, creating confusion about actual capacity
- 23,600 cooling BTU falls short of advertised 2 Ton capacity (24,000 BTU), limiting performance in hot climates
- Single-stage condenser cannot modulate cooling capacity, unlike the variable-speed furnace side
Who Should Buy
Best For
Homeowners in regions with balanced heating and cooling seasons looking to replace 10 to 15-year-old systems without paying for premium variable-capacity equipment. Budget-conscious contractors serving suburban retrofit markets where modulating heat and solid cooling efficiency matter most.
Consider Alternatives If
Anyone in extreme hot climates or who needs precise capacity matching should evaluate 3-ton units or systems with two-stage cooling capability.
Installation
The unit measures 34.5 inches tall, 17.5 inches wide, and 28.75 inches deep, fitting standard closet or utility room spaces. Suction and liquid line sizing at 3/4 inch and 3/8 inch respectively follow Goodman's field-proven standards. Requires 115V single-phase power with 12.4 to 20-amp breaker availability. PVC exhaust venting eliminates the need for metal ductwork and simplifies outdoor termination, a real advantage during retrofit work.
Warranty & Reliability
Goodman backs this system with a 10-year parts and labor warranty when you register online after installation. This aligns with industry standard coverage and provides financial protection against compressor, heat exchanger, and blower motor failures. Registration is straightforward and unlocks the full coverage period without requiring additional service contracts.
Specifications
| SKU | LS38343850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 23,600 |
| Heating BTU | 60,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71.5 |
| Weight (in lbs) | 22.000000 |
| Feature | Spec |
| Replaces | GSX16S241 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 20 amps |
| Min. Breaker Size | 12.4 amps |
| Tonnage | 3 Ton |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installations Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Style | A-Coil |
| AHRI Certificate Number | 7424264 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |