Independent Review · Updated June 2026

2 Ton 16 SEER 80% AFUE 60,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow

Budget-friendly 2-ton Goodman system delivers solid 16 SEER cooling and 80% AFUE heating

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
2 Ton 16 SEER 80% AFUE 60,000 BTU Goodman Gas Furnace and Air Conditioner System - Upflow
Current Price
$1909
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This Goodman system is ideal for homeowners upgrading older equipment on a tight budget who need reliable heating and cooling without premium pricing. At $1,909, it delivers respectable 16 SEER cooling efficiency and two-stage heating in a compact upflow configuration that fits most utility closets and basements.

Review

The Goodman TX2N4A is a straightforward, no-nonsense split system designed for contractors and homeowners who need functional heating and cooling without premium pricing. This 2-ton unit bundles an air conditioner and furnace in one upflow configuration, making it suitable for basements, utility closets, and attics in single-family homes and small commercial applications. Goodman's reputation for durability and parts availability makes this an accessible entry point for budget-conscious buyers upgrading aging equipment.

Performance specs show solid mid-tier equipment. The air conditioner delivers 24,000 BTU cooling capacity with 16 SEER efficiency, meaning reasonable summer electric bills and Energy Star qualification. The furnace generates 60,000 BTU heating output at 80% AFUE, converting four-fifths of fuel energy into heat. Two-stage operation on both sides allows the system to modulate output based on demand, reducing short-cycling and improving comfort compared to single-stage equipment. Maximum airflow reaches 1,600 CFM through the variable-speed blower.

Pros & Cons

Pros

  • Energy Star certified with 16 SEER rating and two-stage compressor for lower cooling costs
  • 80% AFUE furnace with two-stage burner provides efficient heating on 60,000 BTU capacity
  • Variable-speed blower motor maximizes comfort and reduces energy waste during partial-load operation
  • Compact dimensions (26 inches tall, 17.5 inches wide, 21 inches deep) fit tight installation spaces
  • 10-year warranty with online registration covers parts and labor on sealed components
  • R410A refrigerant and scroll compressor technology offer proven reliability

Cons

  • 80% AFUE is serviceable but trails high-efficiency 95% AFUE models by 15 percentage points on heating
  • 71 dB noise level runs moderately loud compared to quieter premium brands
  • Requires metal exhaust flue, limiting installation flexibility in some retrofit scenarios

Who Should Buy

Best For

Homeowners in moderate climates replacing 10-to-15-year-old systems who prioritize upfront savings over premium efficiency. Small residential properties, rental units, or secondary homes where monthly utility costs matter less than equipment reliability.

Consider Alternatives If

Buyers in extremely cold climates should explore 95% AFUE furnaces, and homeowners seeking the quietest operation available should audition models under 68 dB.

2 Ton 16 SEER 80% AFUE 60,000 BTU Goodman Gas Furn
$1909
Buy at HVACDirect →

Installation

Installation requires standard 208/230V single-phase power with 15.7 to 20-amp breaker capacity. The upflow configuration suits basement or closet placement with clearance for metal exhaust flue venting. Technicians need basic HVAC skills to connect refrigerant lines (3/8 inch liquid, 3/4 inch suction), route ductwork, and configure the two-stage blower. Most qualified contractors complete installation in 6-8 hours on straightforward retrofit jobs.

Warranty & Reliability

Coverage includes a 10-year parts and labor warranty on all sealed components when you register online with Goodman. This protects compressor, coils, and major components, though coverage may vary by region and requires professional installation. Evaporator coil coverage is included under separate Goodman documentation. Registration is straightforward and must occur within 30 days of activation.

Specifications

SKUTX2N4A
Brand/ManufacturerGoodman
Cooling BTU24,000
Heating BTU60,000
RefrigerantR410A
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)71
Weight (in lbs)2.500000
FeatureSpec
AHRI Certificate Number204633301
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorVariable Speed
Maximum CFM1600
ConfigurationUpflow / Downflow
Burner StagesTwo
Fuel TypePropane, Natural Gas
Height26"
Width17.5"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Energy StarYes
SEER1 (Efficiency)16
Condenser StagesTwo Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size20 amps
Min. Breaker Size15.7 amps
Tonnage3 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line3/4"
StyleA-Coil

Frequently Asked Questions

Why is this system 2-ton for cooling but the specs list 3-ton tonnage? +
The tonnage confusion stems from furnace design. This unit pairs a 24,000 BTU (2-ton) air conditioner with a 60,000 BTU furnace rated at approximately 3-ton capacity. AHRI certificate 204633301 confirms the cooling capacity. The furnace side is oversized for heating-dominant climates. Always reference cooling tonnage for sizing purposes.
Can I install this horizontally in an attic instead of upflow? +
Yes, this model supports both upflow and horizontal configuration. However, horizontal installation typically requires custom ducting arrangements and may need modified support mounting. Verify your installer has proper horizontal installation brackets and that your attic structure accommodates the 26-inch height and 1,600 CFM airflow requirements.
Is 16 SEER good enough, or should I pay more for 18+ SEER? +
16 SEER is respectable for budget equipment. A 18-20 SEER upgrade might save 10-15% on cooling costs annually but costs significantly more upfront. At $1,909, this unit offers strong value. Premium models justify costs only if you plan 15-plus year ownership in hot climates and use air conditioning heavily.
How does Goodman's reliability compare to Lennox or Carrier? +
Goodman trades premium brand perception for competitive pricing and equal reliability on core components. Independent data shows similar compressor longevity across manufacturers. Goodman parts availability is excellent for technicians. The real difference lies in contractor support networks and warranty enforcement, not equipment durability.
What does the 10-year warranty actually cover if something breaks? +
Online registration activates coverage for compressor, heat exchanger, evaporator coil, and sealed components. Most repairs are free parts and labor. Exclusions typically include refrigerant top-ups, wear items, and improper installation damage. Review your registration confirmation for regional limitations.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.