Review
The Goodman 3.5 ton gas furnace and air conditioner system bridges affordability and performance in a market crowded with budget and luxury extremes. This upflow unit delivers 80,000 BTU heating capacity with 96% AFUE efficiency, while the 42,000 BTU cooling side operates at 13 SEER. It's built to handle residential applications where owners want reliable comfort without premium pricing. The A-coil configuration with variable-speed blower motor suggests engineering focused on practical efficiency gains.
Heating performance centers on the 96% AFUE rating, meaning only 4% of fuel energy is wasted up the flue. The two-stage burner adjusts output based on demand, reducing cycling losses during mild weather. Cooling delivers 42,000 BTU at 13 SEER using R410A refrigerant and a single-stage reciprocating compressor. The variable-speed ECM blower achieves 1600 CFM maximum airflow, enabling better dehumidification and zone control compared to single-speed motors. Energy Star certification confirms this system meets federal efficiency thresholds.
Pros & Cons
Pros
- 96% AFUE furnace efficiency maximizes heating performance with natural gas or propane, minimizing wasted fuel
- 13 SEER air conditioning meets Energy Star standards, reducing cooling costs in summer months
- Variable-speed ECM blower motor optimizes airflow at 1600 CFM maximum, improving comfort and dehumidification
- Two-stage burner operation allows furnace to run at lower capacity during mild heating days, saving energy
- 10-year parts warranty with online registration provides solid protection against manufacturing defects
Cons
- Single-stage compressor in AC unit means no modulation, leading to higher operating costs in very hot climates
- 75 dB noise level runs slightly louder than premium models, which may be noticeable in quiet homes
- Reciprocating compressor design is less efficient than scroll compressors found in higher-tier systems
Who Should Buy
Best For
Homeowners in regions with balanced heating and cooling demands who prioritize fuel efficiency and want a dependable, mid-range system. Contractors installing replacements in moderate climates will appreciate the straightforward design and easy upflow configuration.
Consider Alternatives If
Those in extreme climates or who demand ultra-quiet operation should look at variable-capacity units or higher SEER systems with scroll compressors.
Installation
Installation requires standard 115V, 1-phase electrical service with breaker capacity between 23.9 and 40 amps, typical for most homes. PVC or plastic exhaust flue venting is required, with the flue positioned on the right side. Suction line comes with 3/8-inch insulation and 30-foot maximum length, allowing flexibility in equipment placement. Upflow/horizontal mounting suits basements and attics where headroom is limited. Sweat valve connections require basic soldering skills or contractor labor.
Warranty & Reliability
A 10-year parts warranty covers manufacturing defects when registered online within 30 days of purchase. This protection applies to compressor, controls, and structural components. Labor and refrigerant are not included, so service calls are owner responsibility. Online registration is simple and extends coverage beyond the standard limited warranty, making it worthwhile for peace of mind.
Specifications
| SKU | ACIQ-4X-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 42,000 |
| Heating BTU | 80,000 |
| Refrigerant | R410A |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 75 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 40 amps |
| Min. Breaker Size | 23.9 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368835 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Upflow / Downflow |
| Flue Location | Right |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |