Independent Review · Updated June 2026

3 Ton 13 SEER 80% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Downflow

Solid 3-ton combo system balancing affordability with reliable mid-tier efficiency

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
3 Ton 13 SEER 80% AFUE 80,000 BTU Goodman Gas Furnace and Air Conditioner System - Downflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
Best for contractors and homeowners seeking a proven, budget-conscious 3-ton system without premium pricing. The 13 SEER cooling and 80% AFUE heating deliver respectable efficiency for retrofit applications and new builds in moderate climates.

Review

Goodman's 3-ton gas furnace and air conditioner system represents a pragmatic middle ground in the residential HVAC market. Marketed through Online Supply and carrying SKU LS38783830, this downflow unit combines an 80,000 BTU furnace with a 36,000 BTU condenser, targeting contractors and homeowners who need dependable performance without cutting-edge efficiency ratings. The system replaces legacy models GSX130362, GSX130363, and GSX130365, signaling continuity in Goodman's lineup.

Performance specs confirm this as a conventional choice. The furnace delivers 80% AFUE efficiency across two burner stages, while the 13 SEER air conditioner operates at single-stage capacity using R410A or R22 refrigerant. A multi-speed blower reaches 1,600 CFM maximum airflow. The reciprocating compressor and sweat valve connections (3/8 inch liquid, 3/4 inch suction) represent field-proven technology. At 74 dB noise output, the unit operates within acceptable residential ranges but runs louder than variable-capacity competitors.

Pros & Cons

Pros

  • 80,000 BTU two-stage gas furnace with 80% AFUE provides balanced heating output and efficiency
  • 13 SEER air conditioner cools 36,000 BTU per hour, adequate for most 3-ton residential loads
  • Multi-speed blower motor with 1,600 CFM maximum offers flexible airflow control
  • Downflow A-coil configuration installs in tight attic spaces and crawlspaces
  • 10-year warranty with online registration protects your investment against manufacturing defects
  • Reciprocating compressor and sweat valve connections use proven, serviceable components

Cons

  • 13 SEER rating is older standard, below current 14+ SEER minimums in many regions
  • 80% AFUE furnace does not qualify for Energy Star certification or rebate programs
  • Single-stage air conditioner compressor lacks variable capacity for part-load efficiency
  • 74 dB noise level runs slightly louder than high-efficiency models

Who Should Buy

Best For

Contractors replacing failed systems on tight budgets and homeowners in moderate climates who prioritize affordability over premium efficiency. This unit suits rental properties, secondary residences, and replace-in-kind upgrades where downflow orientation fits existing ductwork.

Consider Alternatives If

Buyers in cold climates needing high-efficiency heating, Energy Star rebate seekers, or homeowners installing brand-new systems who can invest in 16+ SEER units for long-term energy savings.

3 Ton 13 SEER 80% AFUE 80,000 BTU Goodman Gas Furn
$0
Buy at HVACDirect →

Installation

Downflow configuration and A-coil design fit attic and crawlspace installations. The unit measures 34.5 inches tall by 17.5 inches wide by 28.75 inches deep, weighing 30 pounds when dry. Electrical requirements are straightforward: 120V single-phase 60 Hz service with 19.1 to 30-amp breaker sizing. Metal exhaust flue is mandatory. Installation demands standard refrigerant line insulation (3/8 inch thickness) and proper ductwork connection.

Warranty & Reliability

Online Supply backs this system with a 10-year parts warranty upon online registration, providing solid protection against compressor failure, valve defects, and component manufacturing errors. This coverage aligns with industry standards for mid-tier equipment. Registration is required to activate the full term, so document your purchase carefully. Labor costs fall to the installer or owner.

Specifications

SKULS38783830
Brand/ManufacturerOnline Supply
Cooling BTU36,000
Heating BTU80,000
RefrigerantR410A or R22
Electrical120 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)30.000000
FeatureSpec
ReplacesGSX130362, GSX130363, GSX130365
Energy StarNo
SEER1 (Efficiency)13
Condenser StagesSingle Stage
Compressor TypeReciprocating
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size19.1 amps
Tonnage3 Ton
Valve TypeSweat
Height34.5"
Width17.5"
Depth28.75"
ResourcesGoodman Brochure Goodman Installation Manual Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationDownflow
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil
Exhaust Flue RequirementMetal
Furnace Efficiency / AFUE80%
Blower MotorMulti-Speed
Maximum CFM1600
Burner StagesTwo
Fuel TypeGas
Suction Line Insulation Thickness3/8"
Length30 feet

Frequently Asked Questions

How does 13 SEER compare to current efficiency standards? +
13 SEER represents mid-2000s technology and no longer meets Energy Star thresholds, which now require 16+ SEER for most regions. You won't qualify for federal tax credits or utility rebates, but the unit will function reliably. Expect modestly higher electric bills versus newer 18+ SEER units.
Will this fit my existing downflow ductwork? +
Yes, if your current system uses A-coil downflow orientation. The 34.5-inch height and 3/8-inch liquid plus 3/4-inch suction lines match standard retrofit dimensions. Verify metal exhaust flue access and 120V electrical availability before installation.
Is the 80% AFUE furnace adequate for cold climates? +
80% AFUE is acceptable in moderate climates but loses competitiveness in regions averaging below 40 degrees Fahrenheit in winter. You'll burn more gas than a 95% AFUE unit. Consider upgrading if heating costs are a priority and your climate experiences harsh winters.
How does single-stage cooling affect summer energy use? +
Single-stage compression runs at full capacity regardless of cooling demand, consuming more electricity during mild 70-75 degree days compared to variable-capacity alternatives. For consistent hot climates, this works fine. In variable climates, two-stage units offer efficiency gains.
What does the 10-year warranty actually cover? +
Parts warranty covers manufacturing defects in the compressor, coil, and controls. Labor, refrigerant, and service calls are excluded. Online registration is required within 30 days of installation to activate coverage.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.