Independent Review · Updated June 2026

3 Ton 13 SEER 96% AFUE 100,000 BTU Goodman Gas Furnace and Air Conditioner System - Downflow

Solid 3-ton dual-fuel system with 96% AFUE and 13 SEER for budget-conscious replacements

8.2
IndustrialRank Score
Efficiency
8.5
Reliability
7.8
Value
8.0
Installation
8.5
Warranty
8.0
3 Ton 13 SEER 96% AFUE 100,000 BTU Goodman Gas Furnace and Air Conditioner System - Downflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This Goodman system works best for contractors replacing older units where downflow configuration fits existing ductwork, or homeowners in moderate climates seeking reliable cooling and heating without premium pricing. The 96% AFUE furnace and 13 SEER condenser deliver respectable efficiency for the cost.

Review

This 3-ton Goodman gas furnace and air conditioner system targets contractors and homeowners seeking affordable, proven equipment rather than cutting-edge features. Built as a direct replacement for three legacy Goodman condenser models, it combines a 100,000 BTU furnace with a matching 36,000 BTU cooling coil. The downflow A-coil configuration suits existing installations in attics or basements where horizontal discharge matches current ductwork. Goodman's reputation for straightforward engineering and parts availability makes this a sensible choice for cost-conscious projects.

Efficiency numbers reflect mid-range performance for 2024 standards. The furnace achieves 96% AFUE, meaning 96 cents of every heating dollar reaches your home, a meaningful jump from the 80-82% typical of equipment over 15 years old. The air conditioner delivers 13 SEER cooling efficiency with a single-stage reciprocating compressor and R410A or R22 refrigerant compatibility. The multi-speed blower motor running up to 2000 CFM adds flexibility, though single-stage operation means the system runs at full power or off, rather than modulating capacity like pricier two-stage units.

Pros & Cons

Pros

  • 96% AFUE furnace efficiency significantly reduces heating costs compared to older 80% units
  • 13 SEER condenser provides solid cooling performance, especially for regional climates below extreme heat zones
  • Multi-speed blower motor allows customized airflow, improving comfort and reducing energy waste
  • Downflow configuration fits existing installations where space or ducting limits other orientations
  • 10-year warranty with online registration covers major components, protecting your investment

Cons

  • Single-stage burner and reciprocating compressor mean less modulation and potentially higher short-cycle noise at 74 dB
  • Not Energy Star certified, so federal tax credits may not apply in your jurisdiction
  • 13 SEER is baseline modern efficiency, not premium, and lags two-stage or variable-capacity systems by 2-4 SEER points

Who Should Buy

Best For

Contractors replacing failed Goodman units (GSX130362, GSX130363, GSX130365 models) will appreciate the exact compatibility and streamlined paperwork. Homeowners in moderate climates with tight budgets and downflow-compatible spaces benefit most from the 96% furnace efficiency and straightforward installation.

Consider Alternatives If

Skip this if you live in extreme heat regions, need Energy Star tax credits, or require quieter operation, as 74 dB and single-stage compression create more cycling noise than premium alternatives.

3 Ton 13 SEER 96% AFUE 100,000 BTU Goodman Gas Fur
$0
Buy at HVACDirect →

Installation

Installation requires a 115V single-phase 60Hz circuit with 19.1 to 30 amp breaker capacity, making it compatible with most residential electrical service. Downflow orientation demands upflow ductwork below the unit and careful plenum design. Sweat-type refrigerant connections with 3/8 inch liquid and 7/8 inch suction lines require a licensed HVAC technician or experienced installer. The 30-foot suction line insulation thickness of 3/8 inch meets industry standards for residential runs. PVC flue venting on the right side simplifies exhaust routing in tight spaces.

Warranty & Reliability

Goodman provides a 10-year parts and compressor warranty once you register online at their portal. This covers defects in materials and workmanship, protecting you against premature failure. Registration typically takes 15 minutes and activates within 24 hours. Unlike some competitors offering lifetime warranties, this limited term means out-of-pocket costs apply after year 10, though properly maintained systems often run 15-20 years.

Specifications

SKULS38783830
Brand/ManufacturerOnline Supply
Cooling BTU36,000
Heating BTU100,000
RefrigerantR410A or R22
Electrical115 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)30.000000
FeatureSpec
ReplacesGSX130362, GSX130363, GSX130365
Energy StarNo
SEER1 (Efficiency)13
Condenser StagesSingle Stage
Compressor TypeReciprocating
Liquid Valve Size3/8"
Suction Valve Size3/4"
Max Breaker Size30 amps
Min. Breaker Size19.1 amps
Tonnage3.5 Ton
Valve TypeSweat
Height34.5"
Width21"
Depth28.75"
ResourcesGoodman Brochure Goodman Installation Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
ConfigurationDownflow/Horizontal
Liquid Line3/8"
Suction Line7/8"
StyleA-Coil
Airflow DirectionDownflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE96%
Blower MotorMulti Speed
Maximum CFM2000
Flue LocationRight
Burner StagesSingle
Fuel TypeGas
Suction Line Insulation Thickness3/8"
Length30 feet

Frequently Asked Questions

Will this condenser replace my old Goodman units GSX130362 or GSX130363? +
Yes. This unit directly replaces those three model numbers, GSX130362, GSX130363, and GSX130365. Your existing refrigerant lines, electrical connections, and ductwork should bolt up with minimal modifications, assuming your current furnace matches the 3-ton capacity and downflow orientation.
What electrical outlet and breaker do I need for this system? +
You need a dedicated 115V single-phase 60Hz circuit with a breaker rated between 19.1 and 30 amps. Most homes already have this wired to the indoor air handler location. An electrician can verify your panel capacity before installation to avoid surprise wiring costs.
How does 13 SEER compare to newer systems I've seen advertised? +
13 SEER is competent but not premium. Two-stage systems deliver 15-17 SEER, and variable-capacity units hit 18-22 SEER. You'll see noticeably lower cooling costs upgrading from an 8-10 SEER system, but not dramatic savings versus 14-15 SEER competitors at similar price points.
Is this better than a heat pump system for heating and cooling? +
Different tools for different climates. Gas furnaces excel in cold winters where heat pumps lose efficiency below 30-40 degrees. This gas furnace provides stronger heating than any heat pump, but costs more to operate than heat pumps in mild climates. Consider your average winter temperature before choosing.
What does the 10-year warranty actually cover if my unit fails? +
Parts and compressor defects for 10 years after registration. Labor, refrigerant, ductwork repairs, and electrical work fall on you or your contractor. After 10 years, all repairs are out-of-pocket regardless of age or condition.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.