Review
The ACiQ 3-ton horizontal furnace-air conditioner system bridges affordability and efficiency for contractors and homeowners seeking reliable mid-range equipment. Built on Goodman's proven platform and rated at 96% AFUE for heating and 13 SEER for cooling, this unit targets the replacement market where older units operate at 80-82% AFUE. The horizontal A-coil design addresses real-world installation constraints in attics and crawlspaces where vertical units simply don't fit. Energy Star certification and available rebates sweeten the financial case.
Performance specs are straightforward and solid. The furnace delivers 100,000 BTU across two burner stages, while the 36,000 BTU air conditioner condenser operates at single-stage capacity with a reciprocating compressor. Cooling capacity tests at 3.5 tons, providing adequate overlap for oversized comfort. The variable-speed ECM blower motor ramps from idle to 2,000 CFM maximum, reducing runtime electricity draw compared to fixed-speed motors. Operating noise measures 74 dB, acceptable for equipment rooms but notable in sensitive spaces. Electrical requirements are modest at 115V single-phase with 19.1 to 30 amp breaker sizing.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs compared to 80-90% baseline units
- 13 SEER air conditioner qualifies for Energy Star, supporting rebates in many regions
- Variable-speed ECM blower motor provides better comfort and quieter operation than fixed-speed alternatives
- Horizontal A-coil configuration fits tight attic spaces where vertical units won't fit
- Two-stage burner and single-stage compressor allow modulated operation for improved efficiency
- 10-year warranty with online registration covers parts and provides good peace of mind
Cons
- 74 dB operating noise is moderate, not the quietest option for noise-sensitive areas
- Single-stage compressor limits part-load efficiency compared to two-stage or variable-capacity designs
- R454B refrigerant still requires trained technicians for service and recovery
- Horizontal configuration requires precise ductwork support and slope management
Who Should Buy
Best For
Homeowners replacing 10-plus year old Goodman systems or building new construction where horizontal mounting in attic spaces makes sense. Contractors doing retrofit work in homes with space limitations will appreciate the compact 21 x 21.125 x 26 inch footprint.
Consider Alternatives If
Budget-conscious buyers seeking the absolute lowest upfront cost should compare standard 14 SEER units, though long-term efficiency gains typically justify the premium. Those prioritizing whisper-quiet operation may want to audition competing models.
Installation
Horizontal configuration requires careful attention to ductwork connection and support. The unit measures 30 inches in length and weighs 120 pounds, manageable for two-person installation but demanding proper framing. Sweat valve connections on both 3/8 inch liquid and 7/8 inch suction lines require competent brazing. PVC exhaust flue is standard. Refrigerant charging with R454B demands EPA certification. Most installations run 4-6 hours for experienced technicians.
Warranty & Reliability
Ten-year parts coverage with online registration provides strong protection against compressor and heat exchanger failure. Registration is mandatory and takes five minutes online. Coverage excludes wear items like capacitors and blower motors in some circumstances, so review terms carefully. Goodman stands behind these units through a national network of authorized service providers.
Specifications
| SKU | ACiQ-36-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 36,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130362, GSX130363, GSX130365 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 19.1 amps |
| Tonnage | 3.5 Ton |
| Valve Type | Sweat |
| Height | 21" |
| Width | 21.125" |
| Depth | 26" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368844 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions