Review
Goodman's horizontal gas furnace and air conditioner system combines heating and cooling into one compact unit designed for tight spaces. The SKU ACiQ-36-EHPD-UPG targets contractors and homeowners upgrading older split systems in attics, crawlspaces, and mobile homes. At 3.5 tons with 36,000 cooling BTU and 80,000 heating BTU, this Energy Star qualified system bridges budget and efficiency concerns without premium brand pricing.
The 97% AFUE furnace rating puts this in the ultra-efficient category, meaning nearly all fuel converts to usable heat. Cooling delivers 13 SEER1 efficiency through a single-stage reciprocating compressor and variable-speed ECM blower. The modulating burner adjusts between stages for finer temperature control, while the 115V single-phase 60Hz electrical requirement keeps installation straightforward. R454B refrigerant and plastic PVC flue compatibility meet current environmental standards.
Pros & Cons
Pros
- 97% AFUE furnace efficiency significantly reduces heating costs compared to standard 80-90% units
- Modulating burner stages provide precise temperature control and better comfort than single-stage alternatives
- 13 SEER1 rating qualifies for Energy Star, potentially unlocking utility rebates worth $300-500
- Variable-speed ECM blower motor adjusts airflow dynamically, improving comfort and reducing runtime noise
- Horizontal A-coil configuration fits cramped attics, basements, or mobile home spaces where vertical units won't fit
- R454B refrigerant future-proofs against upcoming EPA phaseouts of older refrigerants
Cons
- Single-stage compressor cannot match two-stage units in part-load efficiency during mild weather
- 74 dB noise level acceptable but louder than premium variable-capacity competitors in cooling mode
- 3.5 ton actual capacity exceeds the 3 ton rating, potentially oversizing for smaller homes and wasting energy
Who Should Buy
Best For
Contractors replacing failed Goodman units GSX130362, GSX130363, or GSX130365 will appreciate the direct compatibility. Homeowners in moderate climates seeking a horizontal furnace-coil combo for attic or basement installation will find the 97% AFUE and 13 SEER efficiency gains meaningful on monthly utility bills.
Consider Alternatives If
Skip this if you need variable-capacity cooling for hot climates or ultra-quiet operation, as single-stage reciprocating compressors cannot match inverter-driven alternatives.
Installation
Horizontal A-coil design requires downflow or horizontal airflow ducting, making it ideal for attic and basement installations. Sweat valve connections use 3/8 inch liquid lines and 3/4 inch suction lines with pre-installed 3/8 inch insulation. The 21 inch by 21.125 inch by 26 inch footprint fits tight spaces where vertical coils cannot. Installation requires 115V single-phase power with a 19.1 to 30 amp breaker.
Warranty & Reliability
Goodman backs this unit with a 10-year parts warranty when you register online after purchase. No labor coverage included, so contractor service calls during year two through ten remain out-of-pocket expenses. This warranty length matches Goodman's mid-tier standard across most product lines and requires proof of professional installation.
Specifications
| SKU | ACiQ-36-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 36,000 |
| Heating BTU | 80,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130362, GSX130363, GSX130365 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 19.1 amps |
| Tonnage | 3.5 Ton |
| Valve Type | Sweat |
| Height | 21" |
| Width | 21.125" |
| Depth | 26" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7424271 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Horizontal |
| Flue Location | Right |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions