Review
The ACiQ 3-ton combo system positions itself as the entry point for homeowners seeking balanced performance without flagship pricing. At $643, this Goodman-manufactured unit combines a 60,000 BTU furnace and 36,000 BTU condenser in a compact upflow A-coil configuration. It's designed for existing ductwork retrofits and new construction where budget constraints matter. The unit carries ENERGY STAR certification and includes manufacturer documentation spanning installation, service, and technical specs.
Performance metrics show real-world relevance. The furnace achieves 98% AFUE with modulating burner stages, meaning it ramps output down on mild heating days instead of cycling on-off. The condenser's 13 SEER rating reflects single-stage operation, delivering 36,000 cooling BTU through reciprocating compression. The variable-speed ECM blower reaches 1200 CFM maximum while running quietly at lower speeds during partial-load conditions. Suction line insulation measures 3/8 inch thick, meeting modern field standards.
Pros & Cons
Pros
- 98% AFUE furnace with modulating burner stages reduces heating costs by up to 25% compared to single-stage units
- 13 SEER air conditioner meets ENERGY STAR standards with R454B low-GWP refrigerant
- Variable-speed ECM blower motor adjusts CFM from low to 1200 CFM, improving comfort and reducing runtime
- Plastic PVC flue compatible, simplifying venting in tight retrofit applications
- 10-year warranty with online registration provides reasonable peace of mind coverage
Cons
- Single-stage condenser limits cooling efficiency gains during partial-load summer operation
- 74 dB noise level is 2-3 dB louder than premium models, noticeable near bedrooms
- R454B refrigerant availability and servicing still inconsistent in some rural markets
Who Should Buy
Best For
Homeowners in moderate climates upgrading from 10+ year old systems who prioritize upfront savings over cutting-edge efficiency. Contractors pricing new construction or value-tier replacements will appreciate the straightforward specs and lower labor complexity.
Consider Alternatives If
Anyone needing high-efficiency cooling in hot climates should compare SEER2 equivalents, as 13 SEER translates to roughly 10.5 SEER2, which trails newer two-stage units.
Installation
Installation requires standard 115V, 60 Hz single-phase power with 19.1 to 30 amp breaker sizing, fitting most residential panels. Sweat valve connections use 3/8 inch liquid and 7/8 inch suction lines. The unit measures 34.5 inches tall, 17.5 inches wide, and 28.75 inches deep, fitting standard closets and utility rooms. PVC flue venting simplifies combustion air routing compared to metal vent requirements on older models.
Warranty & Reliability
The 10-year parts warranty activates upon online registration, protecting against compressor failure and heat exchanger defects. Registration typically takes 15 minutes through the Goodman portal. This coverage aligns with industry mid-tier standards but falls short of 12-year warranties on premium units. No labor coverage is included, so service calls cost $150-250 after warranty expiration.
Specifications
| SKU | ACiQ-36-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 36,000 |
| Heating BTU | 60,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130362, GSX130363, GSX130365 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 19.1 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
| Resources | Goodman Brochure Goodman Installations Instructions Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Information Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow/Horizontal |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| AHRI Certificate Number | 7424264 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |