Review
The ACiQ 3-ton cased coil represents the practical middle ground in residential air conditioning. Positioned as a direct replacement for Goodman GSX130362, GSX130363, and GSX130365 models, this unit targets contractors performing system upgrades where equipment compatibility matters as much as performance. The vertical 21-inch configuration solves a real installation problem, fitting attics and closets that reject standard horizontal coils. At 36,000 BTU cooling capacity and 13 SEER efficiency, it's not exotic, but it's exactly what many residential retrofits need.
Performance numbers tell a grounded story. The 13 SEER1 rating delivers measurable efficiency improvement over 10-SEER legacy equipment without pushing into premium pricing territory. The reciprocating compressor runs single-stage, meaning it cycles on and off rather than modulating, which is common at this price point. The 74 dB noise level is honest, not whisper-quiet, but acceptable for utility closets and attics. Electrical specs stay straightforward: 208/230 volt single-phase operation with 19.1 to 30-amp breaker sizing fits standard residential panels. The R454B refrigerant keeps you current with environmental regulations without retrofit complexity.
Pros & Cons
Pros
- 13 SEER efficiency balances operating costs with affordability, realistic for most residential retrofits
- Vertical 21-inch cased coil fits constrained spaces where horizontal coils won't work
- Direct GSX130362, GSX130363, GSX130365 replacement eliminates compatibility guesswork
- R454B refrigerant aligns with modern environmental standards and equipment
- 30-amp breaker compatibility works with standard residential electrical panels
Cons
- 74 dB noise level is noticeably louder than premium variable-speed units, concerns noise-sensitive homeowners
- Single-stage compressor lacks efficiency gains from modulating or two-stage designs
- No Energy Star certification means missing potential utility rebates in some regions
Who Should Buy
Best For
Contractors performing equipment swaps in homes with existing Goodman GSX condensers will appreciate the direct replacement compatibility. Homeowners upgrading older 10-SEER systems on tight budgets and those with space constraints benefit from the vertical cased coil design and reasonable efficiency bump.
Consider Alternatives If
Skip this unit if you need Energy Star certification for rebate programs, prioritize quiet operation near bedrooms, or want variable-speed compressor technology for premium efficiency in new construction.
Installation
Installation follows familiar patterns for contractors. Sweat valve connections use standard 3/8-inch liquid and 3/4-inch suction lines, with a 3/8-inch insulation thickness on the suction side. The 30-foot included lineset cuts most onsite work. Upflow and downflow configuration flexibility adapts to existing ductwork. The 26-inch height, 21-inch width, and 21-inch depth fit tight spaces where horizontal coils fail. Standard nitrogen purging and evacuation procedures apply. Budget 2 to 4 hours for straightforward changeouts.
Warranty & Reliability
The 10-year warranty requires online registration but provides solid coverage for parts and labor through Goodman's network. This reflects Goodman's confidence in the reciprocating compressor design, which trades complexity for durability. Registration is straightforward and typically completed at installation. The warranty doesn't cover refrigerant or damage from poor maintenance, so proper airflow and filter changes remain the homeowner's responsibility.
Specifications
| SKU | ACiQ-36-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 36,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130362, GSX130363, GSX130365 |
| Energy Star | No |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 19.1 amps |
| Tonnage | 3.5 Ton |
| Valve Type | Sweat |
| Height | 26" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | Upflow / Downflow |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/8" |
| Length | 30 feet |
Frequently Asked Questions