This Goodman 3-ton combo lands squarely in the sweet spot for contractors seeking an affordable yet capable heating and cooling system. The horizontal configuration makes it practical for attic and crawlspace applications, while the 120,000 BTU furnace speaks to serious heating demand. At 96% AFUE and 16 SEER1, the specifications suggest a system built for efficiency-conscious buyers without premium pricing.
Performance data reveals a well-balanced design. The furnace delivers 120,000 BTU across two stages, meaning it ramps from low fire during mild days to full 120,000 BTU capacity when outdoor temperatures plummet. The 3.5-ton condenser produces 34,800 BTU of cooling at 16 SEER1, better than the 15 SEER advertised. A variable-speed ECM blower motor with 2,000 CFM maximum capability modulates airflow to match actual demand, reducing energy waste. The scroll compressor is proven reliable, though single-stage operation means no capacity adjustment in mild weather.
Pros & Cons
Pros
- Exceptional 96% AFUE furnace efficiency reduces heating costs significantly in northern climates
- 16 SEER1 rating on 3.5-ton condenser exceeds the 15 SEER baseline advertised
- Dual-stage burner and two-stage heating provide modulated comfort and efficiency
- Variable-speed ECM blower motor adjusts to actual heating and cooling demand
- Horizontal configuration with A-coil suits tight attic or crawlspace installations
- 120,000 BTU capacity handles large homes or poorly insulated structures effectively
Cons
- Single-stage compressor cannot modulate cooling capacity, reducing efficiency in mild weather
- 73.5 dB noise level at full operation may be noticeable in quiet environments
- R410A or R22 refrigerant options create uncertainty about which system you'll receive
- Requires 115V single-phase electrical service, limiting compatibility with some older installations
Who Should Buy
Best For
Northern homeowners with 3-ton cooling needs and high winter heating demands will appreciate the 96% AFUE furnace and strong 120,000 BTU output. Contractors installing systems in attics or crawlspaces benefit from the horizontal configuration and compact 24.5-inch height.
Consider Alternatives If
Homeowners in mild climates should consider a true variable-capacity system, since the single-stage compressor wastes efficiency during shoulder seasons.
Installation
Installation requires standard 115V single-phase 60 Hz power with breaker sizing between 18.7 and 30 amps. The horizontal A-coil footprint measures 24.5 inches tall, 21.125 inches wide, and 26 inches deep, fitting tight attic spaces. Plastic or PVC exhaust flue is required. Lineset runs up to 50 feet with 3/4-inch suction line insulation. Professional installation by licensed HVAC technicians is strongly recommended for proper refrigerant charging and ductwork balancing.
Warranty & Reliability
A 10-year parts warranty covers the entire system when you complete online registration with Goodman. This is a solid baseline protection that covers compressor failure, motor burnout, and component defects. Registration should be completed within 30 days of installation to activate full coverage. Warranty does not cover installation labor, ductwork modifications, or damage from improper service.
Specifications
| SKU | LS38783850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 34,800 |
| Heating BTU | 120,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 73.5 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 30 amps |
| Min. Breaker Size | 18.7 amps |
| Tonnage | 3.5 Ton |
| Height | 24.5" |
| Width | 21.125" |
| Depth | 26" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368842 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |