Review
The Goodman 3-ton split system occupies a practical middle ground in the residential HVAC market. At $732 for a complete furnished unit from Online Supply, it delivers certified efficiency without premium pricing that keeps many homeowners stuck with aging equipment. The system carries AHRI certification number 7424264, Energy Star qualification, and addresses real installation constraints with PVC exhaust capability. This positioning appeals particularly to contractors managing cost-conscious customers and homeowners recovering from equipment failure without substantial savings.
Performance metrics tell a straightforward story. The air conditioning component delivers 17 SEER2 efficiency with 35,000 BTU cooling capacity using a two-stage scroll compressor, meaning it runs at reduced capacity during mild days rather than cycling constantly. On the heating side, the modulating furnace produces 60,000 BTU input at 97% AFUE, matching burner fire to actual demand instead of running at full blast. The variable-speed ECM blower modulates from near-silent to 1,200 CFM maximum depending on heating or cooling load, reducing parasitic fan energy losses typical of single-speed equipment.
Pros & Cons
Pros
- 17 SEER2 rating delivers real cooling efficiency gains, approximately 25% better than 13-year-old equipment
- 97% AFUE furnace with modulating burner matches heating output to actual demand, reducing waste and runtime
- Two-stage scroll compressor minimizes noise at 71 dB while providing flexible capacity management
- Variable-speed ECM blower optimizes airflow and reduces fan energy consumption
- Energy Star certified with rebate potential offsetting initial investment
- PVC exhaust flue requirement simplifies installation on many existing homes
Cons
- Product listing shows conflicting cooling BTU specs (title claims 60,000 but specifications show 35,000 cooling BTU, which is standard for 3-ton but creates confusion)
- 10-year warranty requires online registration, creating friction point for some homeowners
- 71 dB noise level is acceptable but not class-leading for two-stage compressors
Who Should Buy
Best For
Homeowners in moderate climates replacing 10+ year old systems where upfront cost matters more than premium features. Contractors serving price-sensitive markets who need AHRI certification and reliable equipment that customers can actually afford.
Consider Alternatives If
Anyone in extreme heat climates needing maximum cooling capacity or buyers prioritizing the quietest possible operation should compare higher-tier models.
Installation
Installation requires standard split-system connections using 3/8-inch liquid line and 7/8-inch suction line with 3/4-inch insulation. The upflow configuration works for basements and attics, though the 30-inch height, 17.5-inch width, and 21-inch depth require typical furnace closet space. The 115V, single-phase 60 Hz electrical requirement demands breaker sizing between 21.3 and 35 amps. PVC exhaust simplifies venting compared to metal flue requirements.
Warranty & Reliability
Ten-year parts coverage activates only with online registration, which many homeowners appreciate as a reliability commitment but occasionally overlook during initial installation. This duration provides meaningful protection during the critical early years while acknowledging that most failures occur within five years. Registration is straightforward but must be completed to validate coverage.
Specifications
| SKU | LS38783850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 35,000 |
| Heating BTU | 60,000 |
| Refrigerant | R410A or R22 |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 30.000000 |
| Feature | Spec |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 18 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Max Breaker Size | 35 amps |
| Min. Breaker Size | 21.3 amps |
| Tonnage | 3 Ton |
| Valve Type | Sweat |
| Height | 30" |
| Width | 17.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7424264 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Furnace Efficiency / AFUE | 97% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow / Downflow |
| Burner Stages | Modulating |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 3/4" |
| Length | 50 feet |