Goodman's horizontal CHPF4860D6 combo system bridges affordability and performance in a crowded market. At $2160, it undercuts many competitors while delivering respectable 18 SEER cooling and 80,000 BTU heating capacity. The unit earned Energy Star status and includes a 10-year warranty with online registration. This system targets homeowners seeking legitimate efficiency upgrades from older single-stage equipment without committing to premium pricing that often exceeds $3000.
The cooling side impresses with an 18 SEER rating, two-stage scroll compressor, and 35,000 BTU output. Two-stage burner operation on the heating side keeps the 80% AFUE furnace from constant cycling, improving comfort during partial-load conditions. The variable-speed blower runs up to 2000 CFM and operates at a reasonable 71 dB. Electrical requirements are modest at 120V single-phase, 60Hz, with a breaker range of 21.9 to 35 amps, making retrofit installations straightforward in most homes.
Pros & Cons
Pros
- 18 SEER cooling efficiency earns Energy Star certification, reducing summer cooling costs significantly
- Two-stage compressor and two-stage burners optimize runtime and reduce energy waste during partial-load operation
- 80,000 BTU furnace with 80% AFUE handles heating adequately for mild-to-moderate winters without excessive fuel consumption
- Variable-speed blower motor adjusts airflow from 0 to 2000 CFM for better comfort control and humidity management
- Horizontal configuration with A-coil design allows flexible installation in attics, basements, or tight spaces
- Scroll compressor technology is proven reliable and quieter than alternatives, running at 71 dB
Cons
- 80% AFUE is serviceable but not competitive with 95%+ AFUE high-efficiency models for heating-dominant climates
- Spec sheet lists 5-ton tonnage while product title claims 3-ton, creating confusion about actual cooling capacity and system sizing
- R410A and R22 refrigerant compatibility adds complexity during service calls and potential future phase-out concerns with R22
Who Should Buy
Best For
Homeowners in moderate climates where cooling needs outweigh heating demands should seriously consider this unit. It works particularly well for those replacing 10-15 year old systems who want solid efficiency gains and two-stage operation without spending $3500 or more on premium equipment.
Consider Alternatives If
Skip this if you live in a heating-dominant climate or need ultra-high efficiency, as the 80% AFUE furnace won't deliver the fuel savings of condensing models.
Installation
Installation complexity is moderate. The horizontal configuration fits attics or basements easily, and sweat valve connections with standard 3/8-inch liquid line and 7/8-inch suction line follow industry norms. Metal exhaust flue is required for the furnace. Technicians should verify ductwork sizing matches the variable-speed blower's capability. Most installations take 4 to 6 hours including refrigerant charging and commissioning.
Warranty & Reliability
Goodman provides 10 years of parts coverage when you register online within 60 days of installation. This is solid mid-market coverage that protects against compressor failure, heat exchanger cracks, and component defects. Labor coverage typically requires extended plans purchased separately. Registration is straightforward and extends protection considerably beyond standard one-year coverage.
Specifications
| SKU | CHPF4860D6 |
| Brand/Manufacturer | Goodman |
| Cooling BTU | 35,000 |
| Heating BTU | 80,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 71 |
| Weight (in lbs) | 77.000000 |
| Feature | Spec |
| Energy Star | Yes |
| SEER1 (Efficiency) | 18 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 35 amps |
| Min. Breaker Size | 21.9 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 24.5" |
| Width | 26" |
| Depth | 21.125" |
| Resources | CHPF Installation Manual CHPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 204633307 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Horizontal |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Style | A-Coil |