Review
The Goodman 4-ton gas furnace and air conditioner system represents a mainstream choice in the mid-market HVAC segment. Manufactured by a company with decades of commercial and residential presence, this upflow unit combines straightforward engineering with proven reliability. At its price point, it competes directly with entry-level units from Lennox and Carrier, appealing to homeowners and contractors who prioritize function over premium features.
Performance metrics reveal a solid, if unspectacular, offering. The furnace delivers 100,000 BTU through two burner stages, achieving 80% AFUE efficiency, which was competitive 10 years ago but lags modern 92-95% models. The air conditioning side produces 48,000 BTU with 13 SEER rating using R410A refrigerant and a reciprocating compressor. The variable-speed blower reaches 2,000 CFM maximum, optimizing airflow in properly sized ducts. Operation at 76 dB is moderately loud, noticeable in quiet residential settings.
Pros & Cons
Pros
- Two-stage burner delivers 100,000 BTU heating output with 80% AFUE efficiency for solid performance in cold months
- Variable-speed blower motor adjusts airflow up to 2,000 CFM for even temperature distribution throughout the home
- 13 SEER cooling efficiency paired with 4-ton capacity handles moderate cooling loads cost-effectively
- Dual fuel capability, accepting both natural gas and propane for flexible installation options
- 10-year warranty with online registration provides reasonable long-term protection against defects
- Compact 30 by 21 by 21 inch footprint fits standard closets and utility spaces
Cons
- 80% AFUE is dated by modern standards, with high-efficiency models now reaching 95% or higher
- 13 SEER rating lacks Energy Star certification, meaning higher cooling energy bills versus 16+ SEER alternatives
- Single-stage condenser cannot modulate cooling capacity, cycling on and off rather than running efficiently at partial load
- 76 dB operating noise level is audible, potentially noticeable in quieter homes or near living areas
Who Should Buy
Best For
Homeowners in moderate climates seeking a budget-friendly replacement for 15+ year old systems will appreciate the balance between cost and performance here. Contractors installing in rental properties or fix-and-flip projects benefit from the reliability and lower upfront investment.
Consider Alternatives If
Skip this if you live in a very cold climate, operate year-round cooling, or want to minimize utility bills, since more efficient models will deliver faster payback.
Installation
This upflow configuration fits standard basement and closet installations. The unit requires 208 to 230 volt single-phase power with 26.3 to 45 amp breaker sizing, typical for residential circuits. Metal flue exhaust venting is mandatory. Standard field connections include 3/8 inch liquid line, 1 1/8 inch suction line with 1/2 inch insulation, and sweat-type valve connections. Most licensed HVAC technicians complete installation in one working day.
Warranty & Reliability
Goodman provides 10 years of parts coverage upon online registration, a reasonable protection period against manufacturing defects and component failure. This covers the compressor, motors, and heat exchanger. Coil warranty extends separately. Homeowner registration is straightforward and required to activate full coverage. Labor and refrigerant are typically excluded.
Specifications
| SKU | LS381183850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 48,000 |
| Heating BTU | 100,000 |
| Refrigerant | R410A |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 76 |
| Weight (in lbs) | 48.000000 |
| Feature | Spec |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Replaces | GSX130483, GSX130484, GSX130485 |
| Energy Star | No |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.3 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions