Review
The ACiQ 4-ton combo system represents a practical middle-ground solution for HVAC replacement projects. Combining a 120,000 BTU furnace with a 48,000 BTU cooling condenser, this downflow configuration addresses both seasonal demands in one integrated package. At $3,136, it positions itself as accessible to budget-conscious contractors and homeowners without sacrificing proven component quality or efficiency ratings that qualify for Energy Star designation.
Performance specifications show solid engineering. The 96% AFUE rating means 96 cents of every heating dollar converts to usable heat, a substantial improvement over legacy 80% AFUE units. The 13 SEER cooling efficiency rating paired with a variable-speed ECM blower motor allows the system to modulate output based on demand, reducing short cycling and energy waste. The two-stage burner enhances comfort by operating at lower capacity during mild weather, extending runtime without temperature swings. Dual-fuel capability accommodates either natural gas or propane, a practical advantage for retrofit situations.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly compared to older 80% AFUE units
- 13 SEER rating qualifies for Energy Star certification and utility rebates in many regions
- Dual-fuel capability supports both natural gas and propane, offering flexibility for different installations
- Two-stage burner and variable-speed ECM blower optimize comfort and reduce runtime cycles
- Compact 30-inch height fits tight spaces, downflow configuration suits basement and attic installations
- 10-year parts warranty with online registration provides solid consumer protection
Cons
- Single-stage compressor limits efficiency gains compared to dual-stage alternatives in mild weather months
- 76 dB noise level is moderately loud for condenser operation, noticeable in quiet residential areas
- R454B refrigerant requires trained technicians familiar with newer low-GWP refrigerants for service calls
Who Should Buy
Best For
Contractors installing complete HVAC systems in homes where space is limited and homeowners seeking reliable mid-range efficiency without premium pricing. This system works well for climates experiencing both significant heating and cooling seasons, where the 96% AFUE and 13 SEER balance makes economic sense.
Consider Alternatives If
Buyers in extremely hot climates should consider higher SEER ratings, and those in primarily heating-focused regions may find a furnace-only solution more cost-effective.
Installation
Installation requires standard line-set connections using 3/8-inch liquid and 1 1/8-inch suction lines, both available in 50-foot lengths. The downflow A-coil configuration fits tight spaces with its 30-inch height. Electrical requirements demand 115V single-phase 60Hz service with breakers between 26.3 and 45 amps. PVC or plastic exhaust flue venting is required. Most experienced HVAC contractors complete installation within one day.
Warranty & Reliability
ACiQ provides a 10-year parts warranty conditional on online registration at time of purchase. This coverage protects against compressor failure, refrigerant leaks, and component defects. The warranty does not cover labor or refrigerant itself. Online registration is straightforward and typically takes five minutes, making warranty activation accessible for most buyers.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 48,000 |
| Heating BTU | 120,000 |
| Refrigerant | R454B |
| Electrical | 115 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 76 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Replaces | GSX130483, GSX130484, GSX130485 |
| Energy Star | Yes |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.3 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| AHRI Certificate Number | 7368845 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions