Review
The ACiQ ACIQ-48-EHPD-UPG combines a high-efficiency gas furnace with integrated air conditioning in one upflow package. This 4 ton system (nominal capacity) replaces older Goodman GSX models and targets cost-conscious contractors and homeowners seeking modern efficiency without full system replacement. The compact 120-pound unit fits standard utility closet installations, making it practical for retrofit projects where space constraints matter.
Performance specifications tell the real story. The furnace delivers 100,000 BTU at 96% AFUE, meaning 96 cents of every fuel dollar converts to usable heat, versus 80-85% in legacy systems. The integrated air conditioner produces 48,000 BTU at 13 SEER1, adequate for moderate cooling loads. Two-stage burner modulation and variable-speed ECM blower optimize efficiency across part-load conditions, reducing runtime costs and noise to 76 dB during standard operation.
Pros & Cons
Pros
- 96% AFUE furnace efficiency reduces heating costs significantly compared to 80-90% models
- Two-stage burner modulates heat output, improving comfort and reducing short-cycling
- Variable-speed ECM blower motor adjusts airflow, lowering energy use and noise to 76 dB
- PVC exhaust compatibility simplifies venting through existing chase or new sidewall installations
- R454B refrigerant future-proofs the system against upcoming EPA phaseouts of older refrigerants
- Compact 30x21x21 inch footprint fits tight utility closets and attic spaces
- 10-year warranty with online registration provides solid coverage for the investment
Cons
- 13 SEER rating is competent but not premium, 14+ SEER models offer faster ROI in high-cooling climates
- Single-stage condenser cannot modulate cooling capacity, reducing efficiency on mild days
- 76 dB noise level runs louder than variable-capacity competitors, noticeable in bedrooms near furnace
- 5 ton condenser mismatch with 4 ton system creates minor capacity imbalance requiring HVAC validation
Who Should Buy
Best For
Contractors replacing aging 80-85% AFUE furnaces in homes where ductwork modifications are minimal or unnecessary. Homeowners in regions with cold winters and moderate summers benefit most, as the high furnace efficiency pays dividends faster than the modest cooling efficiency.
Consider Alternatives If
Buyers in hot climates prioritizing air conditioning efficiency or those needing premium quiet operation should explore single-stage variable-capacity units or higher SEER alternatives.
Installation
Upflow configuration suits basement and utility closet placement with horizontal or vertical return air drops. PVC exhaust venting simplifies installation compared to metal flue requirements, allowing routing through exterior walls or roof without expensive chimney modification. Sweat-type refrigerant connections require brazing skills. Electrical demands 26.3 to 45 amp breaker at 208/230V single-phase, standard in residential service.
Warranty & Reliability
ACiQ offers 10 years parts and labor coverage when registered online after installation. This competitive warranty protects against compressor failure, heat exchanger defects, and component burnout. Registration is free and typically completed during commissioning, making activation simple for informed contractors and homeowners.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 48,000 |
| Heating BTU | 100,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 76 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| AHRI Certificate Number | 7368836 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Product Features | Rebate Available |
| Furnace Efficiency / AFUE | 96% |
| Blower Motor | Variable Speed - ECM |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Energy Star | No |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 30" |
| Width | 21" |
| Depth | 21" |
| Resources | CAPT Installation Manual CAPT Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Replaces | GSX130483, GSX130484, GSX130485 |
| SEER1 (Efficiency) | 13 |
| Condenser Stages | Single Stage |
| Compressor Type | Reciprocating |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.3 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.