Review
The Goodman 4-ton combo system sits squarely in the value segment of HVAC offerings, combining an 80% furnace with R410A cooling and ENERGY STAR qualification. At the budget price point, this configuration appeals to cost-conscious homeowners and contractors managing replacement projects where mid-tier efficiency meets code compliance. The unit carries Goodman's reputation for dependable baseline equipment, though it competes directly with Bryant and Carrier entry-level lines at similar price levels.
Performance numbers reveal a system built for simplicity over sophistication. The furnace delivers 80,000 BTU heating output through a single-stage burner, while cooling capacity sits at 48,000 BTU with a single-stage scroll compressor running on R410A refrigerant. The surprisingly strong 16 SEER2 rating outperforms its 14 SEER2 nameplate, suggesting competitive engineering at this price tier. Multi-speed blower operation reaches 2000 CFM, enabling adequate air distribution across typical 2000-3000 square foot homes.
Pros & Cons
Pros
- ENERGY STAR certified with 16 SEER2 rating, exceeding the 14 SEER2 nameplate specification
- 80,000 BTU furnace output handles most residential heating loads with single-stage burner simplicity
- 5-ton condenser paired with A-coil design offers flexible installation options for upflow configurations
- Multi-speed PSC blower with 2000 CFM maximum capacity provides consistent airflow control
- Sweat-type valve connections use standard 3/8 inch and 7/8 inch line sizes for technician familiarity
Cons
- Single-stage compressor lacks variable capacity, missing efficiency gains from two-stage or modulating units
- 80% AFUE is entry-level by modern standards, newer models achieve 95% efficiency
- 74 dB noise level runs moderately loud compared to scroll compressor units in quieter applications
Who Should Buy
Best For
Homeowners in moderate climates needing a straightforward replacement system without premium costs, and contractors installing for price-sensitive clients where 80% furnace efficiency meets local codes. This unit works well in regions with mild winters where the single-stage burner isn't undersized.
Consider Alternatives If
Anyone in harsh climates needing maximum heating efficiency should explore 90%+ AFUE models, and those prioritizing whisper-quiet operation should consider scroll compressors rated below 72 dB.
Installation
Installation requires standard 120V single-phase 60Hz electrical service with breaker sizing between 26.4 and 45 amps, typical for residential installations. The A-coil upflow design suits most existing ducts and return air plenums. Technicians need metal flue piping at the top exit, and the compact dimensions (33 inches tall, 21 inches wide, 28.75 inches deep) fit standard closet or utility spaces. Sweat connections demand basic soldering competency.
Warranty & Reliability
Goodman provides 10 years of coverage when registered online, protecting compressor and sealed components against defects. This matches competitor baseline warranties but requires proactive registration within 30 days. Labor and refrigerant remain homeowner responsibility, limiting real-world protection compared to extended plans covering service calls.
Specifications
| SKU | LS381183850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 48,000 |
| Heating BTU | 80,000 |
| Refrigerant | R410A |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 48.000000 |
| Feature | Spec |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.4 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 33 3/8" |
| Width | 21" |
| Depth | 28 3/4" |
| Resources | Goodman Brochure Goodman Installation Manual Goodman Parts Manual Goodman Service Manual Goodman Specifications Goodman Technical Information Goodman User Manual Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Configuration | High Airflow |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Style | A-Coil |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Multi Speed - PSC |
| Maximum CFM | 2000 |
| Flue Location | Top |
| Burner Stages | Single |
| Fuel Type | Gas |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |