Review
The Goodman 4 ton combo system positions itself in the practical middle ground of residential HVAC equipment. This upflow configuration pairs an 80% AFUE furnace with a single-stage R410A air conditioner, designed for straightforward replacement installations in homes where ductwork is already established. Online Supply prices this unit competitively, and the Energy Star certification signals baseline efficiency compliance. The system handles both heating and cooling from one package, simplifying contractor logistics and reducing installation footprint compared to split systems.
Performance specs reveal a utilitarian approach to comfort. The furnace delivers 120,000 BTU heating output across two burner stages, while the cooling side produces 48,000 BTU at 14 SEER efficiency. The multi-speed blower can move up to 2000 CFM, allowing contractors to match airflow to existing ductwork during commissioning. At 74 decibels, noise levels stay reasonable for residential settings. However, the single-stage compressor cannot vary capacity, meaning the system runs at full bore on mild days rather than modulating down, which impacts seasonal efficiency averages.
Pros & Cons
Pros
- Two-stage burner on furnace delivers better temperature control than single-stage units and reduces short-cycling
- 14 SEER cooling efficiency meets Energy Star standards, translating to meaningful savings on summer utility bills
- Multi-speed blower motor optimizes airflow for both heating and cooling modes across the 2000 CFM range
- Scroll compressor design is proven reliable with minimal moving parts and established service parts availability
- 80% AFUE furnace rating is respectable for non-condensing units and handles 120,000 BTU heating output effectively
- 10-year warranty with online registration provides reasonable peace of mind on sealed components
Cons
- 14 SEER rating lags behind modern 16-20 SEER systems, limiting long-term energy savings in high-cooling climates
- 80% AFUE furnace wastes 20% of fuel energy compared to 95%+ condensing models, costing more annually in cold regions
- Single-stage compressor cannot modulate cooling capacity, reducing efficiency during mild weather and increasing wear cycles
- Spec sheet shows conflicting tonnage data (listed as both 4 ton and 5 ton), raising questions about accuracy
Who Should Buy
Best For
Homeowners in moderate climates replacing 15+ year old systems who value reliability over cutting-edge efficiency gains. Contractors seeking proven equipment for cost-conscious customers where the heating load justifies the 120,000 BTU output and space constraints favor upflow A-coil design.
Consider Alternatives If
Anyone in severe cold climates should look at 95% AFUE condensing furnaces, and customers in hot, humid regions should consider 16+ SEER variable-capacity systems for better year-round economics.
Installation
Installation is straightforward for licensed contractors familiar with furnace and AC work. The unit requires 120V single-phase 60Hz power with a breaker sized between 26.4 and 45 amps, accommodating most residential panels without upgrades. Refrigerant lines use standard 3/8 inch liquid and 1 1/8 inch suction connections with 1/2 inch insulation supplied (50 feet length). Metal exhaust flue is mandatory. The A-coil design and upflow orientation fit typical attic or basement installations without major modifications.
Warranty & Reliability
Goodman provides 10 years of parts warranty when registered online, covering compressor, heat exchanger, and sealed components. This is middle-tier protection, shorter than some competitors offering 10/10 or 10/5 splits but reasonable for the price point. Registration is straightforward and strongly recommended. Labor is not covered, so budget separately for service calls beyond the parts guarantee period.
Specifications
| SKU | LS381183850 |
| Brand/Manufacturer | Online Supply |
| Cooling BTU | 48,000 |
| Heating BTU | 120,000 |
| Refrigerant | R410A or R22 |
| Electrical | 120 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 48.000000 |
| Feature | Spec |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 16 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 45 amps |
| Min. Breaker Size | 26.4 amps |
| Tonnage | 5 Ton |
| Valve Type | Sweat |
| Height | 30" |
| Width | 24.5" |
| Depth | 21" |
| Resources | CAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Multi-Speed |
| Maximum CFM | 2000 |
| Configuration | Upflow / Downflow |
| Burner Stages | Two |
| Fuel Type | Gas |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Style | A-Coil |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |
Frequently Asked Questions
Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.