Review
The Goodman 4-ton R454B system represents solid mid-market value in the packaged HVAC category. This 14 SEER air conditioner paired with an 80% AFUE furnace sits squarely in the sweet spot for homeowners balancing equipment costs against reasonable efficiency improvements. Goodman's reputation for straightforward engineering and parts availability makes this configuration a reliable choice across residential applications. The 46,000 BTU cooling and 47,000 BTU heating capacity covers typical single-family homes in moderate climates.
Performance metrics reveal a capable but not cutting-edge system. The 14 SEER rating delivers meaningful savings compared to 10-13 SEER units still operating in many homes, though newer 16-18 SEER models pull further ahead. The furnace's single-stage 47,000 BTU output maintains consistent heating without modulation, meaning steady fuel consumption whether demand is 30 percent or 100 percent of capacity. Cooling output reaches 46,000 BTU, handled by a scroll compressor pulling 26.4 to 40 amps at 208/230V single-phase. The 2,000 CFM maximum airflow with multi-speed blower supports efficient distribution.
Pros & Cons
Pros
- 14 SEER cooling efficiency qualifies for ENERGY STAR certification and utility rebates
- 80% AFUE furnace with 47,000 BTU heating output handles most residential heating loads efficiently
- Scroll compressor design is field-proven for durability with minimal nuisance failures
- R454B refrigerant uses lower global warming potential than older R410A formulations
- Multi-speed PSC blower motor allows staged airflow matching for better comfort control
Cons
- Single-stage compressor and furnace burner lack modulation for variable load efficiency
- 74 dB noise level runs noticeably louder than premium variable-speed systems during cooling cycles
- 10-year warranty requires online registration and provides no parts coverage beyond standard manufacturer terms
Who Should Buy
Best For
Budget-conscious homeowners replacing 10+ year old systems who prioritize dependable operation over premium efficiency ratings. This unit suits moderate climate zones where extreme heating or cooling demands don't require high-stage capacity.
Consider Alternatives If
Anyone in hot climates needing aggressive cooling efficiency should consider 16+ SEER systems, and those in cold regions may need higher BTU furnaces or dual-stage burners.
Installation
Installation demands standard residential HVAC practices. The unit requires a metal exhaust flue with top-exit configuration, typical for most homes. Refrigerant lines use 3/8 inch liquid and 1 1/8 inch suction sizing with 1/2 inch insulation thickness. The 50-foot pre-charged line set simplifies field connections. Electrical setup needs 26.4 to 40 amp breaker service at 208/230V single-phase. Most certified technicians complete installation within one day for standard configurations.
Warranty & Reliability
The 10-year parts warranty requires online registration at Goodman's site to activate. Coverage includes compressor, scroll components, and heat exchanger defects under normal residential use. The warranty does not cover labor, refrigerant, or damage from improper installation, lack of maintenance, or non-factory modifications. Registration is straightforward but mandatory, so document your serial number immediately after installation.
Specifications
| SKU | ACIQ-48-EHPD-UPG |
| Brand/Manufacturer | ACiQ |
| Cooling BTU | 46,000 |
| Heating BTU | 47,000 |
| Refrigerant | R454B |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Warranty | 10 Years with Online Registration |
| Decibel Level (dBA) | 74 |
| Weight (in lbs) | 120.000000 |
| Feature | Spec |
| Configuration | High Airflow |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Tonnage | 4 Ton |
| Style | A-Coil |
| Height | 38.25" |
| Width | 35.5" |
| Depth | 35.5" |
| Resources | Goodman Specifications Goodman Customer Brochure Goodman Installation Instructions Goodman Kit Instructions Goodman Parts Manual Goodman Service Manual Goodman Warranty You will need Adobe® Acrobat® Reader to view PDF documents. |
| Safety Information | PROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here. |
| Exhaust Flue Requirement | Metal |
| Furnace Efficiency / AFUE | 80% |
| Blower Motor | Multi Speed - PSC |
| Maximum CFM | 2000 |
| Flue Location | Top |
| Burner Stages | Single |
| Fuel Type | Gas |
| Replaces | GSZ140491 |
| Product Features | Rebate Available |
| Energy Star | Yes |
| SEER1 (Efficiency) | 14 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Max Breaker Size | 40 amps |
| Min. Breaker Size | 26.4 amps |
| Valve Type | Sweat |
| Suction Line Insulation Thickness | 1/2" |
| Length | 50 feet |