Independent Review · Updated June 2026

Goodman 4 Ton 14 SEER 92% 80,000 BTU Furnace & AC System - R410A Upflow

Solid mid-tier efficiency with R454B for budget-conscious replacements

7.1
IndustrialRank Score
Efficiency
7.5
Reliability
7.2
Value
7.8
Installation
7.9
Warranty
7.5
Goodman 4 Ton 14 SEER 92% 80,000 BTU Furnace & AC System - R410A Upflow
Current Price
$0
Check Price at HVACDirect → Shop Now at HVACDirect
Authorized dealer · Full manufacturer warranty
// Bottom Line
This ACiQ system works best for homeowners replacing older Goodman units in moderate climates who want reliable, entry-level efficiency without premium pricing. The 92% AFUE furnace and 14 SEER1 cooling make it practical for cost-conscious upgrades, though it trails higher-tier systems in performance.

Review

The ACiQ ACIQ-48-EHPD-UPG is a no-frills residential heating and cooling system positioned as a budget-friendly replacement for aging Goodman furnace-condenser pairs. Manufactured under the ACiQ brand, which operates as Goodman's value-tier division, this unit targets contractors managing maintenance calls and homeowners watching their upgrade budgets. The upflow/horizontal configuration and compact dimensions make it suitable for standard residential installations, though its performance sits firmly in the entry-level tier.

Performance specs tell a straightforward story. The furnace delivers 47,000 BTU output at 92% AFUE, matching current mid-range standards. Cooling capacity reaches 46,000 BTU with a 14 SEER1 rating, qualifying for ENERGY STAR but trailing premium 16-18 SEER systems. The scroll compressor operates at single-stage capacity, cycling on and off rather than modulating. Maximum airflow hits 2,000 CFM through the multi-speed blower, adequate for most residential ducts. At 74 dBA, the unit produces noticeable noise during operation.

Pros & Cons

Pros

  • 92% AFUE furnace efficiency paired with 14 SEER1 cooling delivers solid all-around performance for residential applications
  • Lightweight 120-pound design simplifies installation and relocation compared to heavier units
  • Compact 21x21x30-inch footprint fits tight mechanical closets and basement installations
  • Multi-speed blower motor provides flexibility in airflow matching for different duct configurations
  • 10-year parts warranty with online registration offers reasonable protection at this price point

Cons

  • R454B refrigerant is lower-pressure than R410A, limiting long-term availability and technician familiarity in some regions
  • 46,000 BTU cooling capacity falls short for larger homes or hot climates requiring more than 4-ton equivalent cooling
  • Single-stage compressor and condenser lack the modulation efficiency of variable-capacity systems during partial-load operation
  • 74 dBA noise level is audible during operation, noticeable in quiet residential settings

Who Should Buy

Best For

Homeowners replacing an aging GSZ140491 or similar Goodman unit in mild-to-moderate climates who prioritize budget over cutting-edge efficiency. Contractors seeking reliable replacement inventory for standard residential retrofits will appreciate the straightforward specs and compact design.

Consider Alternatives If

Anyone in hot climates needing maximum cooling capacity, homes with ductwork sized for 5-ton units, or buyers unwilling to work with R454B refrigerant should look at competing 16 SEER or higher models.

Goodman 4 Ton 14 SEER 92% 80,000 BTU Furnace & AC
$0
Buy at HVACDirect →

Installation

Installation complexity is moderate. The unit requires 208/230V single-phase power with 26.4 to 40-amp breaker sizing. Suction line insulation is 1/2-inch thick, with suction and liquid lines sized at 1 1/8-inch and 3/8-inch respectively, fitting standard refrigerant connections. The plastic PVC exhaust flue and right-side flue location simplify furnace venting. Technicians should note the R454B refrigerant requires proper evacuation and charging procedures.

Warranty & Reliability

ACiQ provides a 10-year parts warranty upon online registration, a reasonable coverage window at this price tier. The warranty does not include labor, meaning major compressor or heat exchanger failure after year five could mean significant out-of-pocket repair costs. Online registration is mandatory to activate coverage, so documentation is critical at installation.

Specifications

SKUACIQ-48-EHPD-UPG
Brand/ManufacturerACiQ
Cooling BTU46,000
Heating BTU47,000
RefrigerantR454B
Electrical208 / 230 V. 1 Phase 60 Hz
Warranty10 Years with Online Registration
Decibel Level (dBA)74
Weight (in lbs)120.000000
FeatureSpec
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
Airflow DirectionUpflow/Horizontal
Exhaust Flue RequirementPlastic / PVC
Furnace Efficiency / AFUE92%
Blower MotorMulti Speed
Maximum CFM2000
ConfigurationUpflow / Downflow
Flue LocationRight
Burner StagesSingle
Fuel TypeGas
Height30"
Width21"
Depth21"
ResourcesCAPF Installation Manual CAPF Specifications Sheet Goodman Evaporator Coil Warranty You will need Adobe® Acrobat® Reader to view PDF documents.
ReplacesGSZ140491
Product FeaturesRebate Available
Energy StarYes
SEER1 (Efficiency)14
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Valve Size3/8"
Suction Valve Size7/8"
Max Breaker Size40 amps
Min. Breaker Size26.4 amps
Tonnage5 Ton
Valve TypeSweat
Liquid Line3/8"
Suction Line1 1/8"
StyleA-Coil
Suction Line Insulation Thickness1/2"
Length50 feet

Frequently Asked Questions

What's the difference between R454B and R410A refrigerant? +
R454B is lower-pressure, more environmentally friendly, and the newer standard as R410A phases out. However, R454B has limited service network availability in some regions, potentially affecting future repairs. Ensure your local technicians stock this refrigerant before purchasing.
Can this unit replace my old Goodman GSZ140491? +
Yes, that's its primary replacement target. However, verify your existing ductwork, electrical service, and line set sizes match the specs. The 46,000 BTU cooling may feel weaker if your original unit was oversized for your home.
Is 14 SEER1 efficient enough for me? +
14 SEER1 is Energy Star compliant and acceptable for mild climates. Homes in hot zones like Arizona or Florida may benefit from 16+ SEER units, which reduce cooling costs significantly. Compare annual energy bills before deciding.
How does this compare to higher-end Goodman or Lennox units? +
Premium systems offer 16-18 SEER, variable-capacity compressors, and quieter operation around 68 dBA. This ACiQ unit sacrifices modulation efficiency and comfort for lower upfront cost, making it ideal for budget-focused replacements rather than optimized comfort.
Do I need to register online for the warranty? +
Yes, online registration is mandatory to activate the 10-year coverage. Without it, you forfeit warranty protection. Complete registration at installation to document your purchase date and activate coverage immediately.

Affiliate disclosure: IndustrialRank earns a commission on qualifying purchases at no extra cost to you. We only recommend products we have independently reviewed.